onnection of inputs on the Standard and -S models
For these two models connection with the DC input screw terminal block
is made by inserting the cables into the cable glands
To carry out the connections, the cables ( 13 to 21mm diameter) must
be passed through the DC cable gland
made to the DC input screw terminal block
accepts cables with a maximum-cross section of 95 mm
minum).
39
17
DC cable installation:
• Open the wiring box front cover
+
-
• Unscrew the DC cable gland
• Introduce the cable with a suitable cross-section
• Connect the cables to the terminals on the DC input screw terminal
block
nect the cables with the right polarity.
• Once connection to the DC input screw terminal block
completed, retighten (8.0 Nm torque) the cable gland firmly and check
seal.
• Check datasheet of terminal block to indicate which kind of cables are
allowed.