2. Remove the thermostat sensing bulb out
of the plastic clip (see Figure 22).
IMPORTANT: Do not force or bend the ther-
mostat sensing bulb or capillary.
3. The thermostat sensing bulb may be locat-
ed to the lower right front side of fireplace.
Determine location of sensing bulb, but
do not mount sensing bulb until step 5. If
you have a masonry fireplace, (see Figure
21 for location). If you have a factory-built
metal fireplace, see Figure 20 for location.
If your fireplace has glass doors, position
sensing bulb directly behind door gap on
right bottom side (see Figure 23).
4. The mounting clip must be a minimum
of 3" from bottom of fireplace to prevent
crimping of capillary. Once you have de-
cided on a location, thoroughly clean the
area. Remove the paper backing from the
adhesive on back of mounting clip (pro-
vided with the heater in hardware pack-
age) (see Figure 19). Press the clip into
the new location so that the thermostat
sensing bulb will be positioned vertically
with the capillary at the bottom (see Figure
24). Slide the thermostat sensing bulb into
the clip.
Figure 19 -Adhesive-Backed Mounting
Mounting
Bracket
Figure 20 - Removing Thermostat
Sensing Bulb
200068-01A
INSTALLATION
Clip
Plastic Clip
Gas Valve
Assembly
Thermostat
Sensing Bulb
www.usaprocom.com
Thermostat
Sensing Bulb
Adhesive-Backed
Mounting Clip
Figure 21 - Installing Thermostat Sensing
Bulb on Masonry Fireplace
Thermostat
Sensing Bulb
Adhesive-Backed
Mounting Clip
Figure 22 - Installing Thermostat
Sensing In Factory-Built Metal Fireplace
Thermostat
Sensing Bulb
Adhesive-Backed
Mounting Clip
Figure 23 - Installing Thermostat Sensing
Bulb behind Glass Door
Capillary
Figure 24 – Position the Thermostat
Sensing Bulb in the Vertical Position
With Capillary at the Bottom
Glass Doors
Thermostat
Sensing Bulb
Adhesive-Backed
Mounting Clip
Do Not Crimp
Capillary
17
Need help?
Do you have a question about the WZN18HLA and is the answer not in the manual?