12P Hex IP
With this feature you can connect the fixtures to one another using the power input and out-
put sockets. The maximum that can be connected is 13 fixtures @ 120V and 20 fixtures @
240V. After the maximum connected fixtures you will need to use a new power outlet.
NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO THE 12P HEX IP AS THE
POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
12P Hex IP
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is "hot"; on
some other DMX devices pin 2 may be 'hot'). Also, check that all cables are connected to the right
connectors; it does matter which way the inputs and outputs are connected.
12P Hex IP
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried
out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog resi-
due, dust, dew).
ADJ Products, LLC - www.adj.com - 12P Hex IP User Manual Page 23
Multiple Unit Power Linking
Trouble Shooting
Cleaning