Important; Installation Specifications; Installation Planning - Dacor EORD227S Installation Instructions Manual

Classic wall oven
Hide thumbs Also See for EORD227S:
Table of Contents

Advertisement

Installation Planning

Observe all governing codes and ordinances during plan-
ning and installation. Contact your local building depart-
ment for further information.

IMPORtANt

• Locate the junction box so that the oven may be easily
disconnected in the event that it needs to be removed
from the wall completely for service.
• If the oven is not installed level it may deliver poor or
inconsistent baking results.
A qualified technician must complete the installation of
this built-in appliance. Proper installation is the respon-
sibility of the customer.
Carefully check the location where the oven is to be
installed. The oven should be placed for convenient
access. Make certain that electrical power, meeting
the specifications on page 4, can be provided in the
selected location.
Cabinet Dimensions
Model
Number
EORS127/
MORS127
EORS130/
MOCS130
EORS136
EORX227/
MORX227
EORX230/
MORX230
X = Number of convection ovens, see page 3
6

Installation Specifications

WARNING
Cabinet tolerances: +1/16 (1.6 mm), -0, unless otherwise stated.
Minimum Cabinet
Width (N)
27" (68.6 cm)
30" (76.2 cm)
36" (91.4 cm)
27" (68.6 cm)
30" (76.2 cm)
Minimum interior cabinet depth: 24" (61.0 cm)
Dacor recommends installing the electrical junction box
in the one of the locations shown.
Install the junction box in a location that allows the
oven to be removed from the the cutout for service
without being disconnected.
Plan the installation so that all minimum clearances
are met or exceeded. Dimensions shown provide mini-
mum clearances, unless otherwise noted. Be certain
that proper clearance is provided for the oven door
when it is in the open position according the Product
Dimensions.
Cabinet cutout dimensions must be used as indicated.
The specified minimum cabinet depth and width must
be provided. The cabinet depth and width must com-
pletely enclose the recessed portion of the oven.
All contact surfaces between the appliance and the
cabinet must be solid and level.
Provide a platform within the cabinet to support the
oven. It must be installed level and straight. The top
edge of the platform must be flush with the cut out at
the front of the cabinet. There are no provisions to level
the oven after it has been installed. 3/4" (1.9 cm) thick
plywood is recommended.
Minimum Cut Out
Minimum Cut out
Width (P)
25 1/2" (64.8 cm)
27 5/8" (70.2 cm)
28 1/2" (72.4 cm)
34 1/2" (87.6 cm)
27 1/2" (69.9 cm)
25 1/2" (64.8 cm)
49 1/8" (124.8 cm)
28 1/2" (72.4 cm)
Height (R)