Product Specifications; Power Supply Requirements; Product Dimensions - Dacor EORD227S Installation Instructions Manual

Classic wall oven
Hide thumbs Also See for EORD227S:
Table of Contents

Advertisement

Power Supply Requirements

It is the owner's responsibility to ensure that a licensed
electrician performs the installation of the electrical sup-
ply for this appliance. The electrical installation, includ-
ing minimum supply wire size, must comply with the
National Electric Code ANSI/NFPA 70 (latest revision)
and local codes and ordinances.
A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be
supplied to the appliance from a dedicated, grounded,
single phase circuit that is protected by a properly sized
circuit breaker or time-delay fuse. If a time-delay fuse is
utilized, fuse both sides of the line (L1 and L2).
The required voltage, frequency and amperage ratings
are listed on the appliance data plate (see page 3) and
in the table for reference.
Preheat times and cavity temperature recovery times
will be increased slightly if operating the unit with less
than a 240 Vac circuit.
This appliance is provided with electrical wiring in a
flexible metal conduit.

Product Dimensions

All tolerances: ±1/16 (±1.6 mm), unless otherwise stated.
Model
Number
EORS127/
MORS127
EORS130/
MORS130
EORS136
EORX227/
MORX227
EORX230/
MORX230
X = Number of convection ovens, see page 3
* Width at light covers on sides
** To top of chassis notch behind control panel
Utility
Cutout
Width (F)
All Models
(12.7 cm)
4

Product Specifications

Overall
Chassis
Width (A)
Width (B)*
26 7/8"
25 3/8"
(68.3 cm)
(64.5 cm)
29 7/8"
28 3/8"
(75.9 cm)
(72.1 cm)
35 7/8"
34 3/8"
(91.1 cm)
(87.3 cm)
26 7/8"
25 3/8"
(68.3 cm)
(64.5 cm)
29 7/8"
28 3/8"
(75.9 cm)
(72.1 cm)
Utility
Utility
Cutout
Cutout
Height (G)
Depth (H)
5"
5 1/4"
(13.3 cm)
(15.2 cm)
Model
Number
EORS127
MORS127
EORS130
MORS130
EORS136
EORS227
MORS227
EORS230
MORS230
EORD227
MORD227
EORD230
MORD230
* Two 120 Vac hot (L1 and L2), one neutral, one ground.
The above specifications are for reference only. See the
appliance data plate (page 3) for exact specifications.
Overall
Chassis
Height (C)
Height (D)**
28 7/16"
27 1/2"
(72.2 cm)
(69.9 cm)
28 1/8"
27 1/4"
(71.4 cm)
(69.2 cm)
49 15/16"
49 1/16"
(126.8 cm)
(124.6 cm)
Control
Notch
Panel
Depth (K)
Depth (J)
6"
1"
1 1/8"
(2.5 cm)
(2.9 cm)
Dedicated Circuit
total Connected
Requirements
5.0 kW (21 Amp.)
240 Vac 60 Hz,
4 wire*, 30 Amp.
5.3 kW (22 Amp.)
240 Vac 60 Hz,
7.8 kW (33 Amp.)
4 wire*, 40 Amp.
240 Vac 60 Hz,
10.0 kW (42 Amp.)
4 wire*, 50 Amp.
Control Panel
Overlay (E)
15/16"
(23.8 cm)
7/8"
(2.2 cm)
7/8"
(2.2 cm)
Chassis
Depth (L)
Height (M)
24"
(61.0 cm)
(2.5 cm)
Load
Notch
1"

Advertisement

Table of Contents
loading