WARNING ating this or any other appliance. • Always contact the Dacor Customer Service Team Hazards or Unsafe practices that COULD result in severe about problems and conditions that you don't under- personal injury or death.
After use. make sure these surfaces have had to the oven. Dacor is n0t responsible for service sufficient time to cool before touching them. required t0 correct a faultY installati0nl The owner is •...
Need If you have questions or problems with installation, contact EO230xxx your Dacor dealer or the Dacor Customer Service Team. For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready. The model and serial number are printed on the product data plate.
Page 7
Top of chassis (32 mm) Control panel 66" (1676 mm) front Flexible conduit Chassis notch Top of chassis side view Single Wall Oven Dimensions Top of chassis (32 mm) Utility cutout Control panel 66" (1676 mm) front Flexible conduit Chassis notch _\-\\\ chassis side view...
Selecting the Location Model Number Carefully check the location where the oven is to be EO127 installed. The oven should be placed for convenient PO127 25 1/2" 56 1/2" 27" access, but away from drafts that may be caused MOV127 (648 mm) (686 mm) (1435 mm)
Page 9
NOTES: • Cutout tolerances: 1/16",-0 (1.6 mm,-0) • 24" minimum cutout depth • 3/4" support platform must be flush with Recommended Recommended electrical electrical front of cutout. See page 8. location location • • • 1" (25 mm) Min. to bottom of 4"...
Cabinet Cut-Out (continued) Support Platform [_ WARNING The top surface of the support platform must be installed flush With the cutout in the front of the cabinet or wall and any trim. Fa!lure to install the Platform properly may cause the exhaust vent to deform and!or become obstructed.
(2) different sizes may be included. ensure a proper installation before proceeding. If replace- Standard oven racks two (2) for a single oven, five (5) ments parts are required, contact your Dacor dealer. for a double oven GlideRack...
Improper connection of the electrical wiring can cause an electric shock hazard and damage the Connecting to a Four Wire Electrical appliance. Dacor is not responsible for damages System resulting from improper installation. Separate the wires coming out of the appliance conduit.
Page 13
Connecting to a Three Wire Electrical Connecting to a Three Wire Electrical Local System-Where Local Codes Permit System with External Ground - Where Codes Permit WARNING 1_ WARNING not conn oct the appliance c0nduit Wire to neutral (white) junction box wire unless local building Do not connect the green appliance wire to the junc- codes permit! tion box or to a cold water pipe unless local building...
Connecting to a Three Wire Electrical System with External Ground - Where Local Codes Permit (continued) Cable from circuit Separate No 10 Min. breaker panel or | copper grounding wire fuse box JunctionREDbOX! I_RED WHITE I_GREEN GREEN Wire nut (4 places) Conduit to wall oven 4 Wire Junction Box Connection...
Page 15
Raise the door so that it is at a 15° angle from the front Support the oven at all times until it is secured into the of the oven. Hold the door with one hand on each side. cabinet. Be certain to take all necessary safety precau- tions.
See page 3 for location. To avoid damage to the door or personal injury from it Dacor is not responsible for the cost of correcting problems falling off its hinges: caused by a faulty installation.
Problems have been noted on the warranty card or dur- ing the on-line activation. Warranty has been activated Oven is wired to all applicable codes and Dacor specifi- on-line or the warranty card has been filled out com- cations. See pages 9 and 10.
Page 19
The Life of the Kitchen? American Made*Family Owned Dacor • 600 Anton Blvd. Suite 1000 Costa Mesa, CA 92626 • Phone: (800) 793-0093 • Fax: (626)403-3130 • www.Dacor.com...
Need help?
Do you have a question about the PO227BK and is the answer not in the manual?
Questions and answers