WARNING • Always contact the Dacor Customer Service Team about problems and conditions that you don’t under- WARNING – NEVER use this appliance as a space stand. See Customer Service Information.
• Do not touch the interior surfaces of the oven during how to turn off electric power to the oven. Dacor use. After use, make sure these surfaces have had is not responsible for service required to correct a sufficient time to cool before touching them.
If You Need Help... Model Identification If you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer Service Team. EO230xxx For repairs to Dacor appliances under warranty call the Dacor Distinctive Service line. Whenever you call, have the model and serial number of the appliance ready.
Page 7
Product Specifications Top of chassis 1 1/4” (3.2 cm) Utility cutout Control panel 66” (167.6 cm) front Flexible conduit Top of Chassis notch chassis side view Single Wall Oven Dimensions Top of chassis 1 1/4” (3.2 cm) Utility cutout Control panel 66”...
Planning the Installation Selecting the Location Model Number • Carefully check the location where the oven is to be EO127 installed. The oven should be placed for convenient 25 ½” 27” 56 ½” MOH127 access, but away from drafts that may be caused by (64.8 cm)
Page 9
Planning the Installation NOtES: • Cutout tolerances: +1/16 (1.6 mm), -0, unless otherwise stated. • 24” minimum cutout depth. Recommended Recommended • 3/4” support platform must be flush with electrical electrical front of cutout. See page 8. location location 1“ (2.5 cm) min. 4“...
Page 10
Planning the Installation Cabinet Cutout (Continued) Support Platform WARNING The top surface of the support platform must be installed flush with the cutout in the front of the cabinet or wall and any trim. Failure to install the platform properly may cause the exhaust vent to deform and/or become obstructed.
Planning the Installation Electrical Specifications It is the owner’s responsibility to ensure that a qualified electrician performs the electrical connection of this appli- ance. The electrical installation, including minimum supply IMPORtANt wire size, must comply with the National Electric Code ANSI/NFPA 70 (latest revision) and local codes and ordi- • Preheat times and cavity temperature recovery times nances.
Connecting to a Four (4) Wire Electrical an electric shock hazard and damage the appliance. System Dacor is not responsible for damages resulting from improper installation. 1. Separate the wires coming out of the appliance conduit. • Connect the ground terminal (or lead) on the appliance 2.
Page 13
Installation Instructions Connecting to a Three (3) Wire Electrical Connecting to a Three (3) Wire Electrical System - Where Local Codes Permit System with External Ground - Where Local Codes Permit WARNING WARNING Do not connect the green appliance conduit wire to the neutral (white) junction box wire unless local building • Do not connect the green appliance wire to the junc- codes permit.
Installation Instructions Connecting to a Three (3) Wire Electrical System with External Ground - Where Local Codes Permit (Continued) Cable from circuit Separate No. 10 min. breaker panel or copper grounding wire fuse box Wire nut Junction box (4 places) WHITE WHITE GREEN...
Page 15
Installation Instructions 3. Raise the door so that it is at a 15° angle from the front 2. Support the oven at all times until it is secured into the of the oven. Hold the door with one hand on each side. cabinet.
• Make sure that the notch on the bottom of each hinge rests on top of the lower lip of each hinge receptacle Dacor is not responsible for the cost of correcting problems before attempting to open the oven door.
Warranty has been activated on-line or the warranty card has been filled out com- □ pletely and mailed. Oven is wired to all applicable codes and Dacor specifi- cations. See pages 9 and 10. □ Oven is level. See page 13.