Network Connection; Connection To Devices; Connection To Other Hubs Or Switches; Power Connection - Advantech ADAM-6520I-AE User Manual

5-port industrial 10/100 mbps
Table of Contents

Advertisement

2.5 Network Connection

2.5.1 Connection to Devices

Each of the switch's twisted-pair ports can be used to connect to a con-
troller or other devices. Use a straight-through twisted-pair cable with RJ-
45 connectors on both ends. The twisted-pair cable extended from a
twisted-pair port is called a "twisted-pair segment". It can be up to 100
meters long. You can connect any RJ-45 (MDI-X) station port on the
switch to any device that uses a standard network interface such as a
workstation or server.

2.5.2 Connection to other Hubs or Switches

ADAM-6520 modules have five RJ-45 ports that support connections to
10 or 100 Mbps Ethernet networks, and half or full-duplex operation.
ADAM-6520 modules can be connected to other hubs or switches via a
two-pair straight through cable or crossover cable. The connection can be
made from any port on ADAM-6520 modules (MDI-X) to other hubs or
switches by either their MDI-X port or uplink MDI port.
ADAM-6520 modules support auto-crossover, so each port allows you to
connect switches together and expand an existing network easily using
either straight through or a crossover Ethernet cable. You can connect any
RJ-45 (MDI-X) port on the switch to a device like a switch, bridge or
router.

2.6 Power Connection

Follow these simple steps to connect ADAM-6520 to power supplies.
1.
Connect the power cable to the two connectors.
2.
Connect the power cable to a power adapter.