Onboard Battery Installation

A battery is included on the mainboard to supply certain volatile memory components
with power when power has been removed from the blade module. If this battery dies, it
must be replaced with an equivalent CR2032 Lithium 3V battery. Dispose of used
batteries according to the manufacturer's instructions. See
installing a new onboard battery.
Warning: There is a danger of explosion if the onboard battery is installed upside down,
which reverses its polarities.
Figure 3-12. Installing the Onboard CR2032 Battery
3-5

Memory Installation

The mainboard of each blade unit must be populated with DIMMs (Dual In-line Memory
Modules) to provide system memory. The DIMMs should all be of the same size and
speed and from the same Super Micro authorized manufacturer due to
compatibility issues. See details below on supported memory and our web site
(www.supermicro.com/products/superblade
Note: For all SBI-7427 series blades, ONLY VLP (Very low profile) memory can be
used.

Populating Memory Slots

The mainboard of a SBI-7127RG-E blade module has eight (8) memory slots,
depending upon the blade model. For optimized memory bandwidth it is strongly
recommended that ALL memory slots in this blade server module be populated by
DIMMs. DIMM layout is shown in
Lithium Battery
Battery Holder
Figure 3-13
3-10
Figure 3-12
for recommended memory.
on the next page.
for a diagram of