Chapter 7, Protocol Logging
Control Commands for Protocol Logging
Logging Port 2 Commands
NOTE:
146
A list of these commands can be displayed by pressing "?" on the computer keyboard.
"a" Pressing the "a" key on the computer keyboard causes the Test Set to display the
active parameters for the access channel.
"b" For internal Hewlett-Packard use only.
"c" Pressing the "c" key on the computer keyboard causes the Test Set to display its
current CDMA channel parameters, such as Walsh code assignments and PN offsets. This
information is settable on the CDMA GENERATOR CONTROL screen.
"f" For internal Hewlett-Packard use only.
"i" For internal Hewlett-Packard use only.
"m" Pressing the "m" key on the computer keyboard causes the Test Set to display the
monitored parameters on the Access Channel. If the Test Set has detected access probes,
this command will show if the information was good or bad via the message CRC
counters.
"o" Pressing the "o" key will toggle a command mode that logs all sync channel
overhead messages. Sync channel messages are continually sent by the Test Set, so be
prepared for a large amount of data. Press "o" again to disable.
"p" Pressing the "p" key will display the current parameters being used on the Paging
Channel.
"q" For internal Hewlett-Packard use only.
"s" Pressing the "s" key will display the current parameters being used on the System
Overhead Message.
"t" Pressing the "t" key will display System Time.