PROGRAM SETTINGS (DIP SWITCH S1)
NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off position.
TIMER-TO-CLOSE ENABLE
This switch enables the auto close timer. The timer to close
feature works in conjunction with the potentiometer located on
the board.
TIMER-TO-CLOSE
ENABLED
S1
ON
ON
1
2
3
4
SLIDE/SWING
This switch selects slide or swing gate operation, in order to
optimize gate behavior for specific application.
SL = Slide • SW = Swing
RIGHT/LEFT OPERATION
This switch selects the gate opening direction, to the left or to
the right. Right/Left operation is determined from the inside of
fence looking out.
"SAVE" SWITCH
This switch stores all settings into memory and locks out changes.
NOTE: For any programming changes to take effect this switch
must be in OFF position. When switch is ON, no settings can be
changed.
PROGRAM SETTINGS (DIP SWITCH S2)
MAGLOCK ENABLE
This switch enables the Maglock feature. On an open command
there will be a half second delay after the maglock relay is
released before the motor starts.
WARNING ENABLE
This switch enables the gate "in motion" alarm feature. The
alarm will beep 3 seconds prior to movement and throughout
movement.
TIMER-TO-CLOSE
DISABLED
S1
ON
ON
1
2
3
4
(Factory Default)
26
TIMER-TO-CLOSE
SWING GATE
S1
ON
ON
1
2
3
4
LEFT HAND
S1
ON
ON
1
2
3
4
LOCKED
S1
ON
APEMs
ON
1
2
3
4
MAGLOCK ENABLED
S2
ON
ON
1
2
3
4
WARNING ENABLED
S2
ON
ON
1
2
3
4
Max = 180 sec
Min = 0 sec
SLIDE GATE
S1
ON
ON
1
2
3
4
(Factory Default)
RIGHT HAND
S1
ON
ON
1
2
3
4
(Factory Default)
UNLOCKED
S1
ON
ON
1
2
3
4
(Factory Default)
MAGLOCK DISABLED
S2
ON
ON
1
2
3
4
(Factory Default)
WARNING DISABLED
S2
ON
ON
1
2
3
4
(Factory Default)

Advertisement