ON/OFF SWITCH POWER WIRING

NOTE: Before running power wiring refer to wiring specifications
on page 15 for correct wire gauges.
Secure all electrical power connections inside the disconnect
switch electrical box. Refer to electrical wiring diagrams on pages
31-33.
IMPORTANT: On three phase operators, power connections must
be properly phased. If phased incorrectly, the gate operator will
run reversed. To correct this situation, shut off power at main
power source and at the operator's electrical disconnect switch.
Then reverse any two of the three power leads.
SINGLE PHASE
All single phase operators will have the following:
115V
• L1 (NEUTRAL), WHITE
• L2 (HOT), BLACK
• GROUND, GREEN
THREE PHASE
All three phase operators will have the following:
• L1 BLACK
• L3 BLACK
STOP/RESET BUTTON CONTROL WIRING (REQUIRED)
1. This control will function as a Stop/Reset command and is to
be wired within line of sight of the gate. The operator will not
function unless this circuit is completed.
2. Wire control station to terminals 3 and 5 in the control box on
the operator.
J1 CONNECTOR
STOP/RESET BUTTON WIRING
1
2
3 4
STOP/RESET
NOTE: For additional control station options refer to pages
21 and 22.
208/230V
• L1 (HOT), BLACK
• L2 (HOT), BLACK
• GROUND, GREEN
• L2 BLACK
• GROUND, GREEN
5
6
7
8 9 10
W I R I N G
ON/OFF Switch
Cover
Wire Nut Connections
(See Instructions)
Power Wiring Conduit
Control Conduit
STOP/RESET
Button
16 16