8 Troubleshooting

Fault
‡ Motor does not start
‡ Motor does not run in auto-
matic mode
‡ The acoustic warning
sounds. (Reduced suction
power)
‡ No suction power during
wet cleaning
‡ The vacuum cleaner
switches off during wet
cleaning
‡ Voltage fluctuations
Cause
> Fuse of the mains socket has
blown.
> Overload protection switch
has tripped.
> Power tool is defective or not
connected properly.
> The power rating of the elec-
trical tool is too low.
> Suction power selected with
suction power control is too
low.
> Hose diameter and switch
position do not correspond.
> Clogged suction hose/nozzle. •
> Filter bag is full.
> Filter element is clogged.
> Tank is full. (Float does not
close the suction opening).
> Tank is full.
> Impedance of power supply is
too high.
Remedy
Connect mains fuse.
Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner can-
not be started again, contact
the Nilfisk service department.
Check that the power tool
works or that the plug is in-
serted correctly.
Note that minimum power rat-
ing is P>40W
Set suction power in accord-
ance with section 4.2.3. „Set-
ting suction power".
Set correct switch position for
hose diameter.
Clean suction hose/nozzle
See section 7.2.2 „Replacing
filter bag".
See section 4.5/4.6 „Cleaning
filter element" and 7.2.5/7.2.6
„Replacing filter element".
Switch off the cleaner. Empty
the tank.
Switch off the cleaner. Empty
the tank.
Connect the cleaner to an-
other socket closer to the fuse
box. Voltage fluctuations over
7% should not occur if the im-
pedance at the transfer point
is ≤ 0.15 Ω .