BEFORE INSTALLATION 
This  appliance  shall  only  be  installed  by  an 
authorized professional.  
This  appliance  shall  be  installed  in  accordance 
with the manufacturer's installation instructions. 
This  appliance  must  be  installed  in  accordance 
with the norms & standards of the country where 
it  will  be  installed.  The  installation  of  this 
appliance  must  conform  to  local  codes  and 
ordinances.  In  the  absence  of  local  codes, 
Installations must conforms to American National 
Standards, National Fuel Gas Code ANSI Z223.1 – 
latest edition** or B149.1. 
The  appliance,  when  installed,  must  be 
electrically  grounded  in  accordance  with  local 
codes or, in the absence of local codes, with the 
National Electrical Code, ANSI/NFPA 70. 
If  local  codes  permit,  a  flexible  metal  appliance 
connection  with  the  new  AGA  or  CGA  certified 
design,  max.  5  feet  (1,5  m)  long,  ½"  I.D.  is 
recommended  for  connecting  this  appliance  to 
the  gas  supply  line.  Do  not  bend  or  damage  the 
flexible connector when moving the appliance.  
This  appliance  must  be  used  with  the  pressure 
regulator  provided.  The  regulator  shall  be 
properly installed in order to be accessible when 
the appliance is installed in its final location. The 
pressure regulator must be set for the type of gas 
to be used. The pressure regulator has ½" female 
pipe  thread.  The  appropriate  fitting  must  be 
determined based on the size of your gas supply 
line, the flexible metal connector and the shutoff 
valve. 
The  appliance  must  be  isolated  from  the  gas 
supply  piping  system  by  closing  its  individual 
manual shutoff valve during any pressure  testing 
of the gas supply piping  system  at test pressures 
equal to or less than ½ psi (3.5 kPa). 
All opening and holes in the wall and floor, back 
and  under  the  appliance  shall  be  sealed  before 
installation of the appliance. 
A manual valve shall be installed in an accessible 
location in the gas line external to the  appliance 
for the purpose of turning on or shutting off gas 
to the appliance 
 
 
Do not use aerosol sprays in the vicinity of this 
appliance while it is in operation 
ROOM  VENTILATION:  An  exhaust  fan  may  be 
used  with  the  appliance;  in  each  case  it  shall  be 
installed  in  conformity  with  the  appropriate 
national  and  local  standards.  Exhaust  hood 
operation may affect other vented appliances; in 
each  case  it  shall  be  installed  in  conformity  with 
the appropriate national and local standards. 
This appliance is shipped from the factory for use 
with  propane  lp  gas.  For  use  with  natural  gas 
please  follow  the 
described  on  pg.  17.  A  step  by  step  conversion 
procedure  is  also  included  with  each  set  of 
natural gas nozzles.  
 
The maximum inlet gas supply pressure incoming 
to  the  gas  appliance  pressure  regulator  is  20'' 
water column (5 kPa) . 
The  minimum  gas  supply  pressure  for  checking 
the regulator setting shall be at least 1" w.c. (249 
Pa) above the inlet specified manifold pressure to 
the  appliance  (this  operating  pressure  is  4"  w.c.     
(1.00 kPa) for Natural Gas and 11" w.c. (2.75 kPa ) 
for LP Gas. 
 
 
 
7
WARNING! 
 
TYPE OF GAS 
conversion  procedure 
GAS PRESSURE 