Weller WX1012 Operating Instructions Manual page 28

Table of Contents

Advertisement

Available languages

Available languages

WX 1
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
7.1
Set parameters
Please observe the overview diagrams (Fig. 7 and Fig. 8, page 10).
Setting the standby temperature
Note The soldering tools have a usage detector (sensor) in the handle
which automatically starts the cooling cycle when the soldering tool
is not in use.
You will find further information about the intelligent tool in the
relevant operating instructions.
The standby temperature is automatically set after a temperature
deactivation.
1. Call up the parameter menu.
2. Select the menu option Standby temperature.
3. Set the standby temperature set-point with the turn-and-click
wheel (5).
4. Confirm the value with the Enter key (6).
5. Exit the parameter menu with key 4.
Set the temperature deactivation value (standby time)
When the soldering tool is not in use, the temperature is reduced to
the standby temperature after the set standby time has elapsed.
Standby mode is indicated as a flashing actual value and the display
reads "Standby" (17).
Press control key 1, or 2 to exit Standby mode. The sensor
integrated tool detects the change in state and deactivates Standby
mode as soon as the tool is moved.
Setting the standby time:
1. Call up the parameter menu.
2. Select and confirm the menu option Standby time.
3. Set the required standby time with the turn-and-click wheel (5).
The following standby settings are possible:
− "OFF" = "0 min": standby time is deactivated (factory setting)
− "ON" = "1-99 min": standby time, individually adjustable
4. Confirm the value with the Enter key (6).
Select further setting parameters in the menu
or
exit the parameter menu with key (4).
Note In the case of soldering work with low heat requirements, the
reliability of the standby function may be impaired.
Setting the automatic switch-off time (AUTO-OFF)
When the soldering tool is not in use, the soldering tool
heater is switched off when the AUTO OFF time expires.
Temperature deactivation is performed independently of the set
standby function. The actual temperature is indicated by flashing
LED and serves as a residual heat display. The display reads
"AUTO-OFF" (16).
11-18