Weller WX1012 Operating Instructions Manual page 21

Table of Contents

Advertisement

Available languages

Available languages

4-18
Fig. 2:
WX 1 with connected
soldering tool
Fig. 3
Fig. 4
Fig. 5
1. Carefully unpack the device.
2. Connect the WX compatible soldering tools (Fig. 1) as follows:
Insert the soldering tool with connector into the connecting socket
(9) on the control unit and turn clockwise to lock.
Fig. 1
3. Place the soldering tool in the holder.
4. Check to make sure that the mains supply voltage matches that
indicated on the rating plate and that the mains power switch (15)
is off.
5. Connect the control unit to the mains supply (13).
6. Switch on the device at the mains power switch (15).
The start-up screen is shown on the display (see Fig. 3).
After switching on the device, the microprocessor carries out a self-
test and reads out the values of the parameters stored in the tool.
When a soldering iron is connected, the display shows the set
temperature (set-point, 22), the temperature units °C/°F (20), the
actual value (actual tool temperature) (21) and the saved fixed
temperatures (24/25) see Fig. 4.
The set-point temperature and fixed temperatures are stored in the
tool. The actual temperature value increases to the set-point
temperature (= soldering tool is heated up).
Note
You will find further connection versions on page 22.
Please adhere to the operating instructions of the connected
devices.
4.1
Setting the temperature individually
Please observe the overview diagrams (Fig. 7 and Fig. 8, page 10).
Setting the fixed temperature
1. Press the required selection key (10). The current set-point
temperature is shown on the display (see Fig. 5).
2. Set the required set-point temperature with the turn-and-click
wheel (5).
3. Confirm the value with the Enter key (6).
4. Press and hold down the required control key 1 or 2 for 3 sec. in
order to save the current set-point as a fixed temperature (under
the key being pressed).
Note
You can find further information about the intelligent tool (e.g. fixed
temperature, factory settings) in the relevant operating instructions.
Select the temperature with control keys 1 or 2
Press the required temperature key 1 or 2.
The tool adjusts to the required temperature.
WX 1