6.3 - Basic Unit Troubleshooting

When I plug my device into the 60Hz 120 Vac Power Outlet, I don't get any power.
The 60Hz 120 Vac Power Outlet produces voltage directly from the power cells. Therefore, the 120Vac
Outlet should function regardless of whether the GPU is plugged in. Before proceeding, make sure the
batteries have a sufficient charge. If the Power Outlet is not on, verify that the 60Hz AC Inverter Power
Switch is in the "ON" position. The LED next to the Inverter Power Switch should be on (see figure 6.3.1).
Is the 60Hz AC Inverter Power Switch On (LED illuminated)?
No: Turn on the 60Hz AC Inverter Power Switch.
6.3.1 60Hz AC Inverter Power set to
"ON" position (LED illuminated)
Is the Inverter On/Off Switch in the "I" position (see figure 6.3.2)?
No: Turn on the Inverter On/Off Switch.
Is the Inverter Display Panel LCD on (see figure 6.3.2)?
No: Contact Tesla™ Industries, Inc.
Is the AC Output Circuit Breaker tripped (see figure 6.3.3)?
No: Proceed to the next step.
Is the 60Hz AC Power Outlet LED illuminated (see figure 6.3.4)?
No: Press the "Reset" button on the Outlet.
Figure 6.3.3 – 60Hz AC Output Circuit
Breaker (push to reset)
If the green LED on the front of the 60Hz AC Power Outlet is illuminated the Outlet should be live. If the LED
does not light after pressing the "Reset" button, contact Tesla™ Industries for further instructions.
TI3000 GPU-24-INV-1800
Troubleshooting & FAQ
Yes: Proceed to the next step.
6.3.2 Inverter Display Panel and
On/Off Switch turned on and active.
Yes: Proceed to the next step.
Yes: Proceed to the next step.
Yes: Push the breaker in to reset.
Yes: Proceed to the next step.
Figure 6.3.4 – 60Hz AC Power Outlet "ON"
(green LED illuminated
(outlined in
blue))