Guidelines When Connecting The Electrical Wiring - Daikin 2AMXM40M4V1B9 Installer's Reference Manual

Hide thumbs Also See for 2AMXM40M4V1B9:
Table of Contents

Advertisement

9.1.2 Guidelines when connecting the electrical wiring

2(A)MXM40+50 + 2(A)MXF40+50
R32 Split series
4P600463-3D – 2021.03
l
DC
DC
AC
k
a DB1 diode bridge
b S90 thermistor lead wire
c LED A
d S40 thermal overload relay lead wire
e S20 (white) room A electronic expansion valve coil
f S21 (red) room B electronic expansion valve coil
g S80 (white) 4-way valve lead wire connector
h S70 fan motor lead wire
i S99 heating lock
j S91 (red) liquid thermistor lead wire
k S92 (white)gas thermistor lead wire
l Multimeter (DC voltage range)
Keep the following in mind:
If stranded conductor wires are used, install a round crimp-style terminal on the
end of the wire. Place the round crimp-style terminal on the wire up to the
covered part and fasten the terminal with the appropriate tool.
b
a
a Stranded conductor wire
b Round crimp-style terminal
Use the following methods for installing wires:
Wire type
Single-core wire
b
a
-
+
j
i
h
g
f
e
Installation method
c b
A
a
a Curled single-core wire
b Screw
c Flat washer
9
Electrical installation
|
c
d
AA´
c
a
Installer reference guide
51

Hide quick links:

Advertisement

Table of Contents
loading