Specific installer safety instructions
Installer reference guide
18
WARNING
Do NOT use locally purchased electrical parts inside the product.
Do NOT branch the power supply for the drain pump, etc. from the terminal
block. This could result in electrical shock or fire.
WARNING
Keep the interconnection wiring away from copper pipes without thermal insulation
as such pipes will be very hot.
DANGER: RISK OF ELECTROCUTION
All electrical parts (including thermistors) are powered by the power supply. Do not
touch them with bare hands.
DANGER: RISK OF ELECTROCUTION
Disconnect the power supply for more than 10 minutes, and measure the voltage at
the terminals of main circuit capacitors or electrical components before servicing.
The voltage MUST be less than 50 V DC before you can touch electrical components.
For the location of the terminals, see the wiring diagram.
Finishing the outdoor unit installation (see
installation" [
4
 55])
DANGER: RISK OF ELECTROCUTION
Make sure that the system is earthed properly.
Turn off the power supply before servicing.
Install the switch box cover before turning on the power supply.
Configuration (see
"11 Configuration" [
CAUTION
When reinstalling the electric box cover, be careful not to pinch the fan motor lead
wire.
Maintenance and service (see
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
"10 Finishing the outdoor unit
4
 56])
"14 Maintenance and
service" [
4
 63])
2(A)MXM40+50 + 2(A)MXF40+50
R32 Split series
4P600463-3D – 2021.03