6
|
Unit installation
6.1.1 Installation site requirements of the outdoor unit
Installer reference guide
26
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
INFORMATION
Also read the following requirements:
▪
"2 General safety
▪
"7.1.3 Refrigerant piping length and height
Mind the following spacing guidelines:
▪
Wall facing 1 side:
>100
b
a
▪
Wall facing 2 sides:
b
a
>50
▪
Wall facing 3 sides:
b
a
>50
a Air outlet
b Air inlet
Allow 300 mm of work space below the ceiling surface and 250 mm for piping and
electrical servicing.
(mm)
>250
NOTICE
▪
Do NOT stack the units on each other.
▪
Do NOT hang the unit on a ceiling.
precautions" [
4
5].
>50
b
>100
>150
b
>150
>300
(mm)
4
difference" [
34].
a
(mm)
a
>50
(mm)
2(A)MXM40+50 + 2(A)MXF40+50
4P600463-3D – 2021.03
R32 Split series