Command: SETF
Purpose:
Response:
Command String:
Description:
Response String:
Description:
Example:
Manual 19854 Rev. D
ECN 50523
Sets the cutoff frequency of the low pass filter.
The module responds with a "0" to tell the calling process the command has
been received.
XYC0ZSETFZ
X—Rack number of the target module (Range: ASCII printable characters, 0
through 3)
Y— Slot number of the target module. (Range: ASCII printable characters, 0
through 7)
C0Z— Module type for the target. Specifying "C01" in this argument addresses
a 443B101, specifying "C02" addresses a 443B102.
SETF— Commands module to change the low pass filter setting.
Z— specifies the low pass filter setting as follows:
"0" turns the low pass filter off.
"1" sets the low pass filter to the 100 Hz cutoff.
"2" sets the low pass filter to the 1kHz cutoff.
"3" sets the low pass filter to the 3 kHz cutoff.
"4" sets the low pass filter to the 10 kHz cutoff.
"5" sets the low pass filter to the 30 kHz cutoff.
"6" sets the low pass filter to the 100 kHz cutoff.
"0"
This return indicates that the command was received by the card.
Command String:
"06C02SETF3"
Response String:
"0"
The low pass filter of the 443B102 in rack 0 and slot 6 is set to the 3 kHz cutoff
frequency.