Command: SVER
Purpose:
Response:
Command Attribute:
Command String:
Response String:
Description:
Example:
Manual 19854 Rev. D
ECN 50523
This command returns the software version number of the firmware in the target
module.
The response string is 5 ASCII printable characters that correspond to the software
version number of the module at the location specified by the command.
This command is supported by all modules using the protocol defined for the 441 series
racks (it is a common or "CMM" command).
XYCMMSVER
Description: X—Rack number of the target module (Range: ASCII printable characters, 0
through 3)
Y— Slot number of the target module. (Range: ASCII printable characters, 0 through 7)
CMM—Module type for the target. Specifying "CMM" in this argument indicates the
intention of any module type that may be found in Rack X, Slot Y. (Range: 3 ASCII
printable characters)
SVER—Commands the target module to return its 5 character software version number.
XX.XX
The first 2 ASCII printable characters are the major revision of
the firmware. The next ASCII printable character is an '.' and is used as a placeholder for
the major and minor revisions of the firmware. The next 2 ASCII printable characters are
the minor revision of the firmware.
Command String:
"04CMMSVER"
Response String:
"03.00"
The software version number of the card in rack 0 and slot 4 is 3.00.