Daikin STREAMER C55WVM Operation Manual page 28

Table of Contents

Advertisement

Troubleshooting
Troubleshooting
„ Air purifying function
Phenomenon
Air purifying capacity is reduced
The air outlet is emitting an odour
No air is being emitted
„ Other
Phenomenon
The fan stops midway through unit
operation
The sound of streamer discharge can
no longer be heard
There is interference on our TV
screen
Just inserting the power supply plug
causes operation to start
27
• Is the unit surrounded by obstacles, or positioned in a place where
airflow cannot reach?
¼ Choose a position that is obstacle-free and from where airflow can
reach all areas of the room.
• Is the pre-filter or dust collection filter dirty?
¼ Clean these parts.
►Page 19, 20
• Is the deodorising filter dirty?
¼ Clean the parts.
►Page 20
• In some cases the air outlet may emit a slight odour as trace amounts of
ozone are generated. However, the amount is negligible and is not harmful
to your health.
• Is the room filled with odours due to cooking or several people
smoking together etc?
¼ The odour will gradually fade as the unit operates.
• Have you moved the unit from another room?
¼ The unit may emit the odour of the room in which it was used previously.
Let the unit run a while longer.
• Is there anything in the room that is emitting an odour continuously?
(Paint, new furniture, wallpaper, sprays, cosmetics, chemicals)
¼ As continuously emitted odours cannot be completely eliminated, you
should ventilate the room at the same time or run the unit in a well-
ventilated room for a short while.
• Is the air outlet or an air inlet blocked?
If they are not blocked, an electrical component is faulty.
¼ Contact the place of purchase.
• When the unit switches to Monitoring mode during operation in ECONO
MODE, the fan turns on and off repeatedly.
• Are the pre-filter, outflow grille, and dust collection filter attached
before the unit is operated?
The fan is configured to stop in order to protect electrical components
if a part is not properly attached.
¼ If a part is not attached, unplug the unit and attach all the parts before
turning the unit on again.
• Depending on the degree of air impurity, streamer operation may turn OFF.
• Is streamer output set to Low?
• Is the TV or radio positioned within 2m of the unit, or is an indoor
antenna positioned near the unit?
• Are the power supply cord or antenna cable of the TV or radio routed
near the unit?
¼ Keep the unit as far as possible from the TV, radio or antenna.
• Did you disconnect the power supply plug during a power failure, or
when a sudden voltage fluctuation occurred? Or did you stop the unit
by disconnecting the power supply plug during the last operation?
¼ The auto-restart function automatically resumes operation.
Check points
Check points
►Page 14
►Page 16
►Page 16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Streamer mc55w

Table of Contents