Daikin STREAMER C55WVM Operation Manual page 27

Table of Contents

Advertisement

Phenomenon
All the FAN lamps (
(Quiet),
(Standard), and
(Turbo)) blink
together
The dust sensor lamp remains
orange or red
The PM2.5 INDICATOR lamp remain
red, purple or brown
There is an odour but the odour
sensor lamp remains green
Sometimes the streamer lamp does
not light up
The streamer lamp blinks even
though the streamer unit has been
replaced
The odour sensor lamp blinks
(Low),
• Are the pre-filter, outflow grille, and dust collection filter attached?
These lamps may blink if the unit is operated without a part attached.
[If one or more parts are not attached]
¼ Unplug the power supply, re-attach the parts and then turn the unit on again.
[If all the parts are attached]
An electrical component is faulty.
¼ Contact the place of purchase.
• Is there a buildup of dust on the pre-filter?
[If there is dust buildup]
¼ Unplug the power supply, clean the pre-filter and then turn the unit on again.
[If there is no dust buildup]
An electrical component is faulty.
¼ Contact the place of purchase.
• Is the air outlet blocked?
[If the air outlet is blocked]
¼ Remove any obstacles blocking the air outlet and then turn the unit on again.
[If the air outlet is not blocked]
An electrical component is faulty.
¼ Contact the place of purchase.
• These lamps may blink if there is a sudden voltage fluctuation.
The lamps will return to their previous condition once voltage returns to normal.
Voltage range protection: 180V-264V
• Is there a buildup of dust in or around the air intake for the dust/PM2.5 sensor?
¼ Vacuum off any dust from the air intake using a cleaner.
• Is the cover detached from the air intake for the dust/PM2.5 sensor?
¼ Securely attach the cover.
• Is the lens for the dust/PM2.5 sensor dirty?
¼ Wipe off dirt from the lens using a dry cotton bud or similar.
• Is the pre-filter dirty?
¼ Clean these parts.
After cleaning, the unit will return to normal operation a short while after being
turned on.
• Did an odour already exist around the time you inserted the power
supply plug?
¼ The basic sensitivity of the odour sensor will be determined by odour
levels in the first minute (approx.) after the power supply plug is inserted
every time.
To adjust the basic sensitivity of the odour sensor, unplug the power supply
when the air is clean (odour-free), wait at least 5 seconds, then re-insert
the power supply plug and turn the unit on again.
• Depending on the degree of air impurity, streamer operation may turn OFF.
The streamer lamp turns off when streamer operation is OFF.
• Is streamer output set to Low?
¼ If it is set to Low, the length of time the streamer operates will be shorter
than when streamer output is set to Regular.
• Is the unit operating in ECONO MODE?
¼ The streamer lamp does not light up when the unit is in Monitoring mode.
• After replacement, was the power supply plug inserted while pressing
on the unit?
• Is the streamer unit's connector properly installed?
[In case of improper installation]
¼ Unplug the power supply, re-attach the connector, and attempt operation
again.
[In case of proper installation]
An electrical component is faulty.
¼ Contact the place of purchase.
• Is the deodorising filter unit attached?
¼ Attach the deodorising filter unit.
Check points
►Page 19
►Page 19
►Page 19
►Page 7
►Page 21
►Page 21
►Page 20
Troubleshooting
►Page 19
►Page 19
►Page 16
►Page 16
►Page 14
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Streamer mc55w

Table of Contents