2.2.1.4.
CIS (Contact Image Sensor) Assembly
Ver. 2.1
(15) Remove the Snap Ring (H7).
(16) Remove the Feed Lever (411).
(17) Remove the Feed Roller Shaft Assembly.
(18) Remove the Feed Roller (419).
Note:
When reinstalling, make sure that the Roller
Assembly is properly placed on the ADF Unit.
(1) Remove 6 Silver Screws (S6).
(2) Remove the Left Cover (612).
(3) Remove 2 Silver Screws (S6).
(4) Remove the Upper Left Cover (329).
37
UF-7000/8000
UF-7100/8100
APR 2007