To remove the transportation stay

Only for RKXYQ5.
NOTICE
If the unit is operated with the transportation stay attached,
abnormal vibration or noise may be generated.
The transportation stay installed over the compressor leg for
protecting the unit during transport must be removed. Proceed as
shown in the figure and procedure below.
1 Slightly loosen the fixing nut (a).
2 Remove the transportation stay (b) as shown in the figure
below.
3 Tighten the fixing nut (a) again.
3
(10.1 N·m)
1
·
2.1.3

To remove the transportation EPS

Only for RKXYQ8.
Remove the EPS. The EPS protects the unit during transport.
3
About the units and options
3.1
About the compressor unit and
heat exchanger unit
The compressor unit and heat exchanger unit are intended for indoor
installation and aimed for air to air heat pump applications.
Installation and operation manual
6
5 HP
8 HP
Ø15.9 mm
Ø19.1 mm
Ø9.5 mm
Ø9.5 mm
a
2
b
Specification
Maximum capacity
Heating
Cooling
Outside ambient
Heating
design temperature
Cooling
Ambient design temperature of
compressor unit and heat exchanger
unit
Maximum relative
Heating
humidity around the
Cooling
compressor unit and
heat exchanger unit
(a)
To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.
3.2

System layout

NOTICE
Design of the system must not be done at temperatures
below –15°C.
a
c
c
VRV DX
b
d
1
In case of VRV DX indoor units
2
In case of VRV DX indoor units combined with an air
handling unit
a
Heat exchanger unit
b
Compressor unit
c
Refrigerant piping
d
User interface (dedicated depending on indoor unit type)
VRV DX
VRV direct expansion (DX) indoor unit
EKEXV
Expansion valve kit
AHU
Air handling unit
3.3

Combining units and options

3.3.1
Possible options for the compressor unit
and heat exchanger unit
For more possible options, see the installer and user reference
guide.
Cool/heat selector
In order to control the cooling or heating operation from a central
location, the following option can be connected:
Description
Cool/heat selector switch
Cool/heat selector cable
Cool/heat selector PCB
With optional fixing box for the
switch
(a)
To install BRP2A81, proceed as follows:
1 Check the components of BRP2A81. You do NOT need all of
them.
a
b
VRV IV compressor unit for indoor installation
5 HP
8 HP
16.0 kW
25.0 kW
14.0 kW
22.4 kW
–20~15.5°C WB
–5~46°C DB
5~35°C DB
(a)
50%
(a)
80%
1
2
VRV DX
VRV DX
EKEXV
AHU
d
d
d
5 HP
8 HP
KRC19-26A
EKCHSC
BRP2A81
KJB111A
c
X
X
X
X
RKXYQ5+8T7Y1B
4P408443-1B – 2016.04
(a)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrv iv rkxyq5t7y1b

Table of Contents