CONTROL BOARD SETUP
Initial Settings
"Timer"
Hold Open Timer
Automatically closes the gate after
the selected amount of time from 1-60
seconds.
Turning the dial between "0" and "OFF"
will disable this feature, requiring a close
command to close the gate.
"ODS"
Obstruction Detection Sensor
Sets the amount of force required to trip
the inherent obstruction sensor.
See page 26 for more details about this
feature.
2 4
"Overlap"
Overlap Delay
For Master/Slave applications. The
control board that has this feature turned
on is the MASTER and will delay to open
for 1-6 seconds. Slave will delay to close.
!
Do not turn this feature on at both
control boards, only the Master.
"Speed"
Motor Speed
Increases or decreases the speed of gate
travel.
VIKING TECHNICAL SUPPORT 1.800.908.0884