Wiring Accessories To The Expansion Board - Chamberlain CSW24UL Installation Manual

Commercial dc vehicular swing gate operator
Table of Contents

Advertisement

Wiring accessories to the expansion board

Refer to the chart below and the corresponding image for a description of the expansion board inputs.
1
Wireless edge
2
Entrapment Protection Device
Inputs (4 terminals total), Open or
Close Direction based on switch
setting next to inputs
3
Single Button Control, SBC (2
terminals)
4
Open Input (& common) (3-Button
Control Station, 4 terminals total)
5
Close Input (& common) (3-Button
Control Station, 4 terminals total)
6
Stop Input (& common) (3-PB
station, 4 terminals total)
7
Exit Loop Input (2 terminals)
8
Shadow Loop Input (2 terminals)
9
Interrupt Loop Input (2 terminals)
EXPANSION BOARD
Connection for wireless edge receiver
EYES ONLY Input: Open or Close Direction Photoelectric Sensors, Close: reverses fully, Open: reverses 4
seconds
EYES/EDGE Input(s): Open or Close Direction Photoelectric Sensors, Infra-red detector wired or Edge
Sensor, reverses 4 seconds
Gate command sequence - Open, Stop, Close, Stop, ... Soft Open ,Soft Close, Soft Stop (maintained
switch does not override external safeties and does not reset alarm condition)
Open command - opens a closed gate.
Soft open (maintained switch does not override external safeties and does not reset alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate.
Close command - closes an open gate.
Soft close (maintained switch does not override external safeties and does not reset alarm condition).
Stop command - stops a moving gate.
Hard stop (maintained switch overrides Open and Close commands and resets alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Overrides an Open or Close command.
Loop wire connection for plug-in loop detector when loop is inside secured area near gate.
Open command - opens a closed gate.
Soft open (maintained switch does not override external safeties and does not reset alarm condition) If
maintained, pauses Timer-to-Close at OPEN limit.
Opens a closing gate and holds open an open gate.
Loop wire connection for plug-in loop detector when loop is positioned under the gate.
Holds open gate at open limit
l
Disregarded during gate motion
l
Pauses Timer-to-Close at Open Limit
l
Loop wire connection for plug-in loop detector when loop is along the side of the gate.
Holds open gate at open limit
l
Stops and reverses a closing gate
l
Pauses Timer-to-Close at Open Limit
l
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite seriesCsw24u

Table of Contents