Wire Accessories To Expansion Board; Photoelectric Sensors And Edge Sensors; Control Station - Chamberlain LiftMaster CSW200101U Installation Manual

Commercial high-traffic ac swing gate operator
Table of Contents

Advertisement

WIRE ACCESSORIES TO EXPANSION BOARD

The EYES/EDGE terminals are used for connecting entrapment protection devices. At least one external monitored entrapment protection device is
required prior to gate movement. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
Only ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the operator so the operator is aware of
the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction.
TERMINALS
FUNCTIONALITY
EYE ONLY and COM
Open or Close Direction Photoelectric Sensors, the functionality is based
on the switch settings (located next to the terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE: gate reverses fully when an obstruction is sensed
Switch set to OPEN: gate reverses 4 seconds when an obstruction is
sensed
TERMINALS
FUNCTIONALITY
SBC and COM
• Gate command sequence - Open, Stop, Close, Stop, ...
• Soft Open, Soft Close, Soft Stop (maintained switch does not
override external safeties and does not reset alarm condition)
OPEN and COM
• Open command - opens a closed gate
• Soft open (maintained switch does not override external safeties and
does not reset alarm condition)
• If maintained, pauses Timer-to-Close at OPEN limit
• Opens a closing gate and holds open an open gate
CLOSE and COM
• Close command - closes an open gate
• Soft close (maintained switch does not override external safeties and
does not reset alarm condition)
STOP and COM
• Stop command - stops a moving gate
• If maintained, pauses Timer-to-Close at OPEN limit
• Overrides an Open or Close command

PHOTOELECTRIC SENSORS AND EDGE SENSORS

CONTROL STATION

WIRING EXAMPLE
WIRING EXAMPLE
33
EYE
1
ONLY
EYE/
2
EDGE
EYE/
3
EDGE
COM
SBC
Photoelectric
EYE
1
Sensor or Edge
ONLY
EYE/
2
EDGE
EYE/
3
EDGE
COM
SBC
Photoelectric
EYE
1
Sensor or Edge
ONLY
EYE/
2
EDGE
EYE/
3
EDGE
COM
SBC
COM
SBC
OPN
CLS
STP
COM

Advertisement

Table of Contents
loading

Table of Contents