Install Vent System; Make Gas Connection - Maytag MGDP575GW Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Install Vent System

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
2.
Connect vent to exhaust hood
Vent must fi t over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
14
12" min.
(305 mm)
12" min.
(305 mm)

Make Gas Connection

1.
Connect gas supply to dryer
Flared
male fi tting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-fl ared male fi ttings. If fl exible metal
tubing is used, be sure there are no kinks.
NOTE: For propane gas connections, you must use pipe-joint
compound resistant to action of propane gas. Do not use
TEFLON
tape.
®†
2.
Plan pipe fi tting connection
A
B
A. 3/8" fl exible gas connector
B. 3/8" dryer pipe
A combination of pipe fi ttings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3.
Open shut-off valve
Closed valve
A
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
Non-fl ared
B
male fi tting
C
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-fl are adapter fi tting
Open valve
B
D

Advertisement