Vent System
Chart
(29" Wide Long Vent Models Only)
Number of
Type
Box/Iouvered,
or
90 ° turns
of vent
Angled hoods
or elbows
0
Rigid metal
120 ft. (36.6 m)
1
Rigid metal
110 ft. (33.5 m)
2
Rigid metal
100 ft. (30.5 m)
3
Rigid metal
90 ft. (27.4 m)
4
Rigid metal
80 ft. (24.4 m)
5
Rigid metal
70 ft. (21.3 m)
Install Vent System
1. install exhaust
hood
.==_--- 12" rnin.
(305 ram)
install exhaust hood and use caulking compound
to seal
exterior wall opening around exhaust hood.
_2. Connect
vent to exhaust
hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest
path possible. Avoid 90 ° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
Make Gas Connection
1. Connect
gas supply to dryer
Flared
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings, if flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound
resistant to action of LP gas. Do not use
TEFLON ®t tape.
2, Plan pipe fitting
connection
B
A. 3/8" flexible gas connector
B. 3/8" dryer pipe
C
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
A combination
of pipe fittings must be used to connect dryer
to existing gas line. A recommended
connection is shown.
Your connection
may be different, according to supply line
type, size, and location.
3.
Open shut-off
valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections
by brushing
on an approved noncorrosive
leak-detection
solution.
Bubbles will show a leak. Correct any leaks found.
12
1®TEFLON
is a registered
trademark
of E.I. Dupont De Nemours
and Company.