Maytag MGDC700VJ - Centennial 7.4 cu. Ft. Gas Dryer Installation Instructions Manual
Maytag MGDC700VJ - Centennial 7.4 cu. Ft. Gas Dryer Installation Instructions Manual

Maytag MGDC700VJ - Centennial 7.4 cu. Ft. Gas Dryer Installation Instructions Manual

27" (69 cm) gas dryer
Hide thumbs Also See for MGDC700VJ - Centennial 7.4 cu. Ft. Gas Dryer:
Table of Contents

Advertisement

Available languages

Available languages

27" (69 CM) GAS DRYER INSTALLATION INSTRUCTIONS
INSTRUCTIONS POUR L'INSTALLATION DE LA SÉCHEUSE
DRYER SAFETY ............................................... 1
INSTALLATION INSTRUCTIONS ................... 2
Tools and Parts ............................................. 2
Location Requirements ................................ 3
Electrical Requirements ................................ 4
Gas Supply Requirements ............................ 4
Venting Requirements................................... 6
Plan Vent System.......................................... 6
Install Vent System........................................ 8
Install Leveling Legs...................................... 8
Level Dryer .................................................... 8
Make Gas Connection .................................. 8
Connect Vent ................................................ 9
Reverse Door Swing (Optional) ................... 9
Complete Installation .................................... 9
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
DANGER
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
W10088974A
À GAZ DE 27" (69 CM)
Table of Contents/Table des matières

DRYER SAFETY

Your safety and the safety of others are very important.
SÉCURITÉ DE LA SÉCHEUSE ..................... 10
Outillage et pièces nécessaires .................. 12
Emplacement d'installation......................... 12
Spécifications électriques ........................... 13
Alimentation en gaz..................................... 14
Mise à niveau de la sécheuse..................... 18
Raccordement au gaz................................. 18
Conduit d'évacuation.................................. 19
de la porte (facultatif) .................................. 19
Achever l'installation ................................... 20
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MGDC700VJ - Centennial 7.4 cu. Ft. Gas Dryer

  • Page 1: Table Of Contents

    27" (69 CM) GAS DRYER INSTALLATION INSTRUCTIONS INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE À GAZ DE 27" (69 CM) Table of Contents/Table des matières DRYER SAFETY ..........1 SÉCURITÉ DE LA SÉCHEUSE ..... 10 INSTALLATION INSTRUCTIONS ....2 INSTRUCTIONS D’INSTALLATION....12 Tools and Parts ..........
  • Page 2: Installation Instructions

    IMPORTANT SAFETY INSTRUCTIONS When discarding or storing your old clothes dryer, remove the door. SAVE THESE INSTRUCTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death. –...
  • Page 3: Location Requirements

    Location Requirements Dryer Dimensions WARNING " (60.3 cm) 43½" (110.5 cm) Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor *29¼" (74.3 cm) for a garage installation. 27"...
  • Page 4: Electrical Requirements

    Special provisions must be made in mobile homes to Gas Supply Requirements introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening. WARNING Electrical Requirements WARNING Explosion Hazard Use a new AGA or CSA approved gas supply line.
  • Page 5 Dryer Gas Pipe Must include a shutoff valve: The gas pipe that comes out through the rear of your dryer In the U.S.A.: has a " male pipe thread. ⁄ An individual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1.
  • Page 6: Venting Requirements

    Venting Requirements Plan Vent System Typical exhaust installations WARNING Typical installations vent the dryer from the rear of the dryer. Other installations are possible. Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire.
  • Page 7 Alternate installations for close clearances Recommended hood styles are shown here. Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions. 4" (10.2 cm) 4" (10.2 cm) A.
  • Page 8: Install Vent System

    Install Vent System Level Dryer 1. Install exhaust hood. Use caulking compound to seal exterior Check the levelness of the dryer. Check levelness first wall opening around exhaust hood. side to side, then front to back. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood.
  • Page 9: Connect Vent

    Remove the 4 screws that attach 2 plugs (D) on the left side. Connect Vent Attach plugs to right side using the same 4 screws. 1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet 9. Insert screws into bottom holes on left side of cabinet. Tighten in dryer.
  • Page 10: Sécurité De La Sécheuse

    INSTRUCTIONS POUR L’INSTALLATION DE LA SÉCHEUSE À GAZ DE 27" (69 CM) SÉCURITÉ DE LA SÉCHEUSE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité...
  • Page 11 IMPORTANTES INSTRUCTIONS DE SÉCURITÉ Avant de jeter ou de ranger votre vieille sécheuse, enlever la porte. CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT : Pour votre sécurité, les renseignements dans ce manuel doivent être observés pour réduire au minimum les risques d’incendie ou d’explosion ou pour éviter des dommages au produit, des blessures ou un décès.
  • Page 12: Instructions D'installation

    INSTRUCTIONS D’INSTALLATION Outillage et pièces nécessaires Emplacement d’installation Rassembler les outils et pièces nécessaires avant de commencer l’installation. Lire et suivre les instructions fournies avec les outils AVERTISSEMENT indiqués ici. Clé à tuyau de 8" ou 10" Couteau Clé à molette de 8" ou Clapets d’évacuation 10"...
  • Page 13: Spécifications Électriques

    Espacements d’installation Il faut prendre des dispositions spéciales pour l’apport d’air de l’extérieur dans la sécheuse lors d’une installation dans une L’emplacement doit être assez grand pour permettre d’ouvrir maison mobile. La surface de toute ouverture pour l’apport complètement la porte de la sécheuse. d’air extérieur (telle qu’une fenêtre à...
  • Page 14: Alimentation En Gaz

    Alimentation en gaz Canalisation d’arrivée de gaz AVERTISSEMENT Un tuyau IPS de ½" est recommandé. Pour les longueurs inférieures à 20 pi (6,1 m), on peut utiliser des tuyaux approuvés de " si les codes et le fournisseur de ⁄ gaz le permettent.
  • Page 15: Exigences Concernant L'évacuation

    Canalisation d’arrivée de gaz de la sécheuse Les produits d’évacuation DURASAFE™ peuvent être achetés chez votre marchand ou en composant le numéro La canalisation d’arrivée de gaz sortant à l’arrière de la de téléphone sans frais indiqué sur la page de couverture sécheuse est dotée d’un filetage mâle de ⁄...
  • Page 16: Planification Du Système D'évacuation

    Planification du système d’évacuation Installations typiques d’évacuation Les installations typiques évacuent par l’arrière de la sécheuse. D’autres installations sont possibles. A. Acheminement standard décalé du conduit d’évacuation par l’arrière B. Acheminement du conduit d’évacuation par la gauche ou par la droite C.
  • Page 17: Installation Du Conduit D'évacuation

    Dispositions spéciales pour les installations dans une maison Si la longueur du circuit est supérieure à la valeur spécifiée mobile dans le tableau, on observera : Le système d’évacuation doit être solidement fixé à une section Une réduction de la longévité de la sécheuse. non combust ble de la structure de la maison mobile et ne doit Une réduction du rendement, avec temps de séchage pas se terminer en dessous de la maison mobile.
  • Page 18: Installation Des Pieds De Nivellement

    Installation des pieds de nivellement Mise à niveau de la sécheuse Contrôler l’aplomb de la sécheuse. Contrôler l’aplomb tout AVERTISSEMENT d’abord transversalement, puis dans le sens avant/arrière. Risque du poids excessif Utiliser deux ou plus de personnes pour déplacer et installer la sécheuse.
  • Page 19: Conduit D'évacuation

    4. Enlever les vis qui fixent les charnières sur la porte. Conduit d’évacuation 5. Enlever les vis au sommet, en bas et sur le côté de la porte (5 vis). En tenant la porte au-dessus de la serviette sur la 1.
  • Page 20: Achever L'installation

    Achever l’installation 1. Vérifier que toutes les pièces sont installées. S’il reste une pièce, passer en revue les différentes étapes pour découvrir laquelle aurait été oubliée. 2. S’assurer d’avoir tous les outils utilisés. 3. Jeter/recycler tous les matériaux d’emballage. 4. Vérifier l’emplacement définitif de la sécheuse. S’assurer que le conduit d’évacuation n’est pas écrasé...