  • Page 2: Copyright

    Copyright FCC and DOC Statement on Class B This publication contains information that is protected by copyright. No part of it may be re- This equipment has been tested and found to comply with the limits for a Class B digital produced in any form or by any means or used to make any transformation/adaptation without device, pursuant to Part 15 of the FCC rules.
  • Page 3: Table Of Contents

    Table of Contents SATA (Serial ATA) Connector ............. 18 SATA (Serial ATA) Power Connector ..........18 LVDS LCD Panel Connector ............19 LCD/Inverter Power Connector ........... 19 Copyright ............2 Expansion Slot ................. 20 Cooling Fan Connector .............. 20 SMBus Connector ..............21 Trademarks ............
  • Page 4: About This Manual

    About this Manual Static Electricity Precautions An electronic file of this manual is included in the CD. To view the user’s manual in the CD, in- It is quite easy to inadvertently damage your PC, system board, components or devices even sert the CD into a CD-ROM drive.
  • Page 5: About The Package

    About the Package The package contains the following items. If any of these items are missing or damaged, please contact your dealer or sales representative for assistance. • 1 SU551 board • 1 COM port cable • 1 Serial ATA data cable •...
  • Page 6: Specifications

    4 x USB 3.0 Storage: 5 to 90% RH MECHANICAL Dimensions 3.5" SBC Form Factor 146mm (5.75") x 102mm (4.02") Display 1 x VGA 1 x DP++ Height PCB: 1.6mm Top Side: 15.5mm, Bottom Side: 4.0mm Chapter 1 Introduction www.dfi.com...
  • Page 7: Watchdog Timer

    USB 2.0. It is a marked improvement set date and time. in device transfer speeds between your computer and a wide range of simultaneously accessible external Plug and Play peripherals. Chapter 1 Introduction www.dfi.com...
  • Page 8: Chapter 2 - Hardware Installation

    AC Power Select SMBus (JP16) SATA Power SATA 2 Chrontel CH7517A COM1-2 COM3-4 SATA 3.0 SATA 0 Intel WGI219LM CPU Fan Buzzer Battery Realtek ALC888S Chassis Intrusion Clear CMOS Data (JP1) Top View Bottom View Chapter 2 Hardware Installation www.dfi.com...
  • Page 9: Block Diagram

    USB 3.0 4x 18.98 USB 2.0 SATA 3.0 USB 2.0 SATA 2x USB 2.0 2x SMBus Digital I/O 8-bit SMBus 96 (X2) LPC Bus 98.40 (X2) RS-232/422/485 2x Super IO RS-232 2x with WDT H/W Monitor Chapter 2 Hardware Installation www.dfi.com...
  • Page 10: System Memory

    2. Set JP1 pins 2 and 3 to On. Wait for a few seconds and set JP1 back to its default setting, Features pins 1 and 2 On. 3. Now plug the power cord and power-on the system. • One 204-pin SODIMM up to 8GB • Single Channel DDR3L 1600MHz Chapter 2 Hardware Installation www.dfi.com...
  • Page 11: Auto Power-On Select

    When using the JP16 “Power On” feature to power the system back on after a power failure occurs, the system may not power on if the power lost is resumed within 5 seconds (power flicker). Chapter 2 Hardware Installation www.dfi.com...
  • Page 12: Mini Pcie Signal Select

    JP13 is used to select the power supplied with the LCD panel. Important: Before powering-on the system, make sure that the power settings of JP13 match the LCD panel’s specification. Selecting the incorrect voltage will seriously damage the LCD panel. Chapter 2 Hardware Installation www.dfi.com...
  • Page 13: Rear Panel I/O Ports

    The DC-in jack on the system board co-lays with a 4-pin right angle connector (optional) or 4-pin vertical Type connector (optional) as the photo displayed below. 4-pin Vertical Type (optional) 4-pin Right Angle (DC-in default) Chapter 2 Hardware Installation www.dfi.com...
  • Page 14: Graphics Interfaces

    VESA, delivers higher performance features than any other digital interfaces. Driver Installation Driver Installation Install the LAN drivers. Refer to Chapter 4 for more information. Install the graphics driver. Refer to Chapter 4 for more information. Chapter 2 Hardware Installation www.dfi.com...
  • Page 15: Usb Ports

    USB port cables to a connector. BIOS Setting Configure the onboard USB in the Advanced menu (“USB Configuration” submenu) of the BIOS. Refer to Chapter 3 for more information. Chapter 2 Hardware Installation www.dfi.com...
  • Page 16: I/O Connectors

    The front audio connector allows you to connect to the line-out and mic-in jacks that are at the front panel of your system. DIO7 Driver Installation DIO6 Install the audio driver. Refer to the Chapter 4 for more information. DIO5 DIO4 DIO3 DIO2 DIO1 DIO0 Chapter 2 Hardware Installation www.dfi.com...
  • Page 17: Com (Serial) Ports

    RD_2 RTS_1 RTS_2 Pin Pin Assignment Pin Pin Assignment TD_1 TD_2 HDD Power Power Button CTS_1 CTS_2 PWR Button HDD-LED Ground SUS_LED DTR_1 DTR_2 Ground LED Power RI_1 RI_2 PWR LED RESET-SW RST Signal SUS_LED Chapter 2 Hardware Installation www.dfi.com...
  • Page 18: Sata (Serial Ata) Connector

    SATA power connector and the other end to your storage device. BIOS Setting Configure the Serial ATA drives in the Advanced menu (“SATA Configuration” submenu) of the BIOS. Refer to Chapter 3 for more information. Chapter 2 Hardware Installation www.dfi.com...
  • Page 19: Lvds Lcd Panel Connector

    Configure the system graphics and the LCD panel in the Advanced menu (the “Video Configuration” submenu) of the BIOS. Refer to chapter 3 for more infor- mation. Note: DFI board's LVDS connector: Hirose DF13-40DP-1.25V(91)/40P/1.25mm; cable side connector: Hirose DF13-40DS-1.25C. Chapter 2 Hardware Installation www.dfi.com...
  • Page 20: Expansion Slot

    Refer to Chapter 3 for more information. To switch between these two signals, use JP7. Refer to the previous section for more informa- tion. SIM Slot (optional) The SIM slot on the system board is used to insert a SIM card. Chapter 2 Hardware Installation www.dfi.com...
  • Page 21: Smbus Connector

    When the system’s power is off and a chassis intrusion occurred, the alarm will sound only when the system restarts. Chapter 2 Hardware Installation www.dfi.com...
  • Page 22: Battery

    Safety Measures • Danger of explosion if battery incorrectly replaced. • Replace only with the same or equivalent type recommend by the manufacturer. • Dispose of used batteries according to local ordinance Chapter 2 Hardware Installation www.dfi.com...
  • Page 23: Chapter 3 - Bios Setup

    To display the submenu, move the highlight to disappears before you respond, restart the system or press the “Reset” button. You may also that field and press <Enter>. restart the system by pressing the <Ctrl> <Alt> and <Del> keys simultaneously. Chapter 3 BIOS Setup www.dfi.com...
  • Page 24: Insyde Bios Setup Utility

    Main Advanced Security Boot Exit This is the help for the Project Name SU551 hour, minute, second BIOS Version 66.27A field. Valid range is from 0 to 23, 0 to 59, 0 to 59. Processor Type Intel(R) Core(TM) i7-6600U CPU @ 2.60GHz...
  • Page 25 TDP. Note: For the “State After G3” setting to take effect, make sure that the "AC Power Loss” option is set to “Always on” in “SIO NUVOTON6106D ” of the “Advanced” menu. Chapter 3 BIOS Setup www.dfi.com...
  • Page 26 Change Values Setup Defaults Exit ←/→ Select Item Enter Select SubMenu Save and Exit  Help ↑/↓ Select Item F5/F6 Change Values Setup Defaults Exit ←/→ Select Item Enter Select SubMenu Save and Exit  Chapter 3 BIOS Setup www.dfi.com...
  • Page 27 HD Audio will be enabled if present and disabled otherwise. RAID Mode This option allows you to create RAID or Intel Matrix Storage configuration on Serial ATA devices. Serial ATA Port 0, 1 and 2 Enable or disable the serial ATA port. Chapter 3 BIOS Setup www.dfi.com...
  • Page 28 Select SubMenu Save and Exit   USB BIOS Support Disabled Disable USB keyboard/mouse/storage support. Enabled Enable USB keyboard/mouse/storage support under UEFI and DOS environment. UEFI Only Enable USB keyboard/mouse/storage support only under UEFI environment. Chapter 3 BIOS Setup www.dfi.com...
  • Page 29 Enable or disable the PCI Express Root Port. Enable or disable Intel ME Intel ® Management Engine firmware flashing. PCIe Speed Select the speed of the PCI Express Root Port: Auto, Gen1, Gen2 or Gen3. Chapter 3 BIOS Setup www.dfi.com...
  • Page 30 1 temperature, the system or CPU fan should be turned on and operate at the designated speed. The range is from 0-127 Fan Speed Count 1 to Fan Speed Count 4 Set the fan speed. The range is from 0 (fan stop)-100% (full speed). Chapter 3 BIOS Setup www.dfi.com...
  • Page 31 Enable or disable the watchdog function. Case Open Enable or disable the case open. AC Power Loss Set the AC power loss to Always off or on to indicate the system power on/off state after the power resumes. Chapter 3 BIOS Setup www.dfi.com...
  • Page 32: Security

    Enable or disable the TPM function. It displays the following options: No Operation: No changes to current state. Disable: Disable and deactivate TPM. Enable: Enable and activate TPM. Clear TPM Remove all TPM ownership contents. Chapter 3 BIOS Setup www.dfi.com...
  • Page 33: Boot

    Enable or disable the booting to USB boot devices. Note: If the boot type is set to UEFI, the method for RAID volume creation will be different. Please refer to Chapter 5 - RAID for more information. Chapter 3 BIOS Setup www.dfi.com...
  • Page 34: Exit

    Please do not remove the AC power Insyde H20FFT (Flash Firmware Tool) Version (SEG) 100.00.08.10 Copyright(c) 2012 - 2016, Insyde Software Corp. All Rights Reserved. Initializing Current BIOS Model name: SU551 New BIOS Model name: SU551 Help ↑/↓ Select Item...
  • Page 35: Notice: Bios Spi Rom

    When the BIOS IC needs to be replaced, you have to populate it properly onto the system board after the EEPROM programmer has been burned and follow the technical person's instructions to confirm that the MAC address should be burned or not. Chapter 3 BIOS Setup www.dfi.com...
  • Page 36: Chapter 4 - Supported Software

    If after inserting the DVD, “Autorun” did not automatically start (which is, the Mainboard Utility DVD screen did not appear), please go directly to the root directory of the DVD and double- click “Setup”. For Windows 10 Chapter 4 Supported Software www.dfi.com...
  • Page 37: Intel Chipset Software Installation Utility

    Intel chipset can be recognized and configured properly in the system. To install the utility, click “Intel Chipset Software Installation Utility” on the main menu. 1. Setup is ready to install the utility. Click Next. 2. Read the license agreement then click Yes. Chapter 4 Supported Software www.dfi.com...
  • Page 38: Intel Graphics Drivers

    1 to 2 minutes (while WinSAT is running) before the Windows 7/Windows 8.1/Windows 10 desktop appears. The “blank screen” period is the time Windows is testing the graphics performance. 2. Read the license agreement then click Yes. Chapter 4 Supported Software www.dfi.com...
  • Page 39: Audio Drivers

    Restarting the system will allow the new software installation to take effect. 5. Click “Yes, I want to restart this computer now” then click Finish. Restarting the system will allow the new software installation to take effect. Chapter 4 Supported Software www.dfi.com...
  • Page 40: Intel Lan Drivers

    1. Setup is ready to install the driver. Click Next. 5. After completing installa- tion, click Finish. 2. Click “I accept the terms in the license agreement” then click “Next”. 3. Select the program featuers you want installed then click Next. Chapter 4 Supported Software www.dfi.com...
  • Page 41 3. Click “Restart Now“ to restart your computer when the installation is complete. To install the driver, click “Kernel Mode Driver Framework” on the main menu. 1. Click “Yes“ to install the update. 2. The update is installed now. Chapter 4 Supported Software www.dfi.com...
  • Page 42: Intel Management Engine Drivers

    1. Setup is ready to install the driver. Click “Next”. 4. Please wait while the prod- uct is being installed. 2. Read the license agreement then click “Next”. 5. After completing installa- tion, click “Finish”. Chapter 4 Supported Software www.dfi.com...
  • Page 43 1. Setup is ready to install the driver. 4. The wizard is ready to begin installation. Click “Install”. 2. Click “Next” to continue. 5. Please wait while the program features are being installed. Chapter 4 Supported Software www.dfi.com...
  • Page 44 The screenshot displayed above is for illustrative purpose only, and may not resemble the actual screen. The SU551 HW Utility features the following tabs: Information, HW Health, HW Health set, Watchdog, DIO and Backlight. Click on the tabs to access information about the board.
  • Page 45 4. Setup is currently installing the driver. After installation has com- pleted, click Next. 2. Read the license agreement care- fully. Click “I accept the terms in License Agreement” then click Next. 5. After completing installation, click Finish. Chapter 4 Supported Software www.dfi.com...
  • Page 46 Chapter 4 5. Setup is now installing the 3. Read the file information then click driver. Next. 4. Setup is ready to install the driver. 6. Click Finish. Click Next. Chapter 4 Supported Software www.dfi.com...
  • Page 47 To install the driver, click “Microsoft Framework 4.5.2” on the main menu. 1. Setup is now extracting files. 4. Click “Finish”. 2. Read the license agreement care- fully. Click “I have read and accept the terms of the License Agree ment” then click “Install”. Chapter 4 Supported Software www.dfi.com...
  • Page 48: Intel Rapid Storage Technology

    To install the driver, click “Intel Rapid Storage Technology” on the main menu. Please refer to Chapter 5 for more information. 2. The setup program is now ready to install the utility. Click “Next”. 3. Click “I accept the terms in the license agreement” and then click “Next”. Chapter 4 Supported Software www.dfi.com...
  • Page 49 Visual C++ package prior to installing the utility. Click “Install”. 5. Select a setup type and then click 8. The setup program is currently “Next”. installing the Microsoft Visual C++ package. 9. Click “Finish”. 6. Click “Install”. Chapter 4 Supported Software www.dfi.com...
  • Page 50 To install the reader, click “Adobe Acrobat Reader 9.3” on the main menu. 1. Click Next to install or click Change Destination Folder to select another folder. 2. Click Install to begin installa- tion. 3. Click Finish to exit installation. Chapter 4 Supported Software www.dfi.com...
  • Page 51: Chapter 5 - Raid

    1. Power-on the system then press <Del> to enter the main menu of the Insyde BIOS. 2. Go to “Advanced” menu, and select the “SATA Configuration” menu. 3. Change the “SATA Mode Selection” to “RAID” mode. 4. Save the changes in the “Save & Exit” menu. 5. Reboot the system. Chapter 5 RAID www.dfi.com...
  • Page 52 6. Press <Enter>. 7. Use the up or down arrow keys to select the strip size and press <Enter>. 8. Enter the volume size and press <Enter>. 9. At the prompt, press <Y> to confirm volume creation. Chapter 5 RAID www.dfi.com...
  • Page 53 4. Read the license agree- ment and click “I accept the terms in the License Agreement.“ Then, click Next. 7. Confirm the installation and click Next. Chapter 5 RAID www.dfi.com...
  • Page 54 Chapter 5 8. Click “Yes, I want to restart this computer now” to complete the installation and then click Finish. Chapter 5 RAID www.dfi.com...
  • Page 55: Chapter 6 - Intel Amt Settings

    Help ↑/↓ Select Item F5/F6 Change Values Setup Defaults Exit ←/→ Select Item Enter Select SubMenu Save and Exit  Un-Configure ME Un-configure ME without password. You can select enabled or disabled. Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 56 MEBx Exit Help ↑/↓ Select Item F5/F6 Change Values Setup Defaults Exit ←/→ Select Item Enter Select SubMenu Save and Exit  Intel(R) ME Password [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 57 Intel(R) Management Engine BIOS Extension v11.0.0.0005/Intel(R) ME v11.0.0.1205 Copyright(C) 2003-15 Intel Corporation. All Rights Reserved. MAIN MENU > Intel (R) ME General Settings > Intel (R) AMT Configuration MEBx Exit [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 58 > User Consent Password Policy <Anytime> > Network Setup Activate Network Access Unconfigure Network Access <Full Unprovision> > Remote Setup And Configuration > Power Control [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 59 KVM Feature Selection <Enabled> KVM Feature Selection <Enabled> Disabled Enabled Menu for FW Redirection Configuration [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 60 < Enabled> Storage Redirection <Enabled> KVM Feature Selection <Enabled> NONE Disabled Enabled [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 61 > Remote Setup And Configuration > Power Control Default Password Only During Step And Configuration Anytime [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 62 Shared/ Dedicated FQDN <Shared> Dynamic DNS Update <Disabled> Dynamic DNS Update <Disabled> Computer Domain Name Disabled Enabled [Enter] = Complete Entry [Esc]= Discard Changes [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 63 <Full Unprovision> > Remote Setup And Configuration > Power Control Full Unprovision [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 64 > TLS PKI > TLS PKI Provisioning Mode:PKI Provisioning server address [ESC] = Exit [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 65 PKI DNS Suffix > Manage Hashes Disabled Enabled [ESC] = Exit [ESC] = Exit [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 66 Mobile: ON in S0, ME Wake in S3, S4-5 (AC only) Manage Hashes [↑↓] = Move Highlight [Enter] = Complete Entry [Esc]= Discard Changes [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 67 Intel(R) Management Engine BIOS Extension v11.0.0.0005/Intel(R) ME v11.0.0.1205 Copyright(C) 2003-15 Intel Corporation. All Rights Reserved. MAIN MENU > Intel (R) ME General Settings > Intel (R) AMT Configuration MEBx Exit Exit [↑↓] = Move Highlight [Enter] = Select Entry [Esc]= Exit Chapter 6 Intel AMT Settings www.dfi.com...
  • Page 68: Appendix A - Troubleshooting Checklist

    4. There is not enough space left on the diskette. Use another diskette with adequate storage 4. Adjust the brightness of the display by turning the monitor’s brightness control knob. space. Appendix A Troubleshooting Checklist www.dfi.com...
  • Page 69: Hard Drive

    Nothing happens when a key on the keyboard was pressed. 1. Make sure the keyboard is properly connected. 2. Make sure there are no objects resting on the keyboard and that no keys are pressed dur- ing the booting process. Appendix A Troubleshooting Checklist www.dfi.com...