Following correction of any alarm, turn the dial control to the OFF position, wait 10 seconds and turn back to desired
setting OR unplug the Stove, wait 10 seconds then restore power.
Alarm
(LED Flashing RED)
1 Flash: Empty
No fuel is delivered to the fire pot to sustain
Hopper
flame
Flame is evident but the exhaust probe is not
able to recognize the hot exhaust temperature
2 Flashes: Exhaust
The exhaust temperature is above or below the
Probe Fail
acceptable range.
The exhaust probe
Exhaust Probe Failure
senses a temperature
of less than negative
20 degrees Celsius or
above 300 degrees
Celsius.
3 Flashes: Ambient
The ambient temperature is above or below the
Probe Alarm
acceptable range.
The ambient probe
Ambient Probe Failure
senses a temperature
of less than negative
20 degrees Celsius
or above 70 degrees
Celsius.
4 Flashes: Missed
Fuel
Ignition
During the ignition
sequence the load
does not ignite. The
Stove will automatically
retry once from the first
failed attempt.
8 Flashes: Exhaust
Fuel
Over Temperature
The exhaust tempera-
ture has exceeded the
allowable temperature.
Convection blower
Installation
pelprostoves.com
Possible Cause
Hopper empty (most likely)
Auger Jam (next likely)
No vacuum
Hopper lid open
Exhaust probe not attached to outlet
Exhaust path is dirty
Not plugged in
Failed component
Not plugged in
Failed component
No fuel
Hopper Empty
Feed Jam
Feed doesn't turn
Feed motor disconnected or failed
Fire pot
Fire pot Dirty so fuel is not near ignition hole
in the fire pot
Igniter
No power
Debris in the end of the igniter chamber
Feed Motor Locked On
Non-approved fuel used
Dirty
Failed
Installation configuration is tight allowing for
limited air circulation around the Stove.
PelPro Pellet Stove • 7104-171C • 10/3/18
Corrective Action
Fill the hopper, inspect the feed tube for jams,
inspect the venting and firebox for obstructions
and clean if necessary, inspect the exhaust
blower to make sure it runs, or close the
hopper lid.
Inspect and clean the exhaust outlet, firebox,
fire pot, and behind the baffles. Inspect the
exhaust probe to see if it is securely attached
to the side of the exhaust outlet.
Plug the probe into the board
Replace the component
Plug the probe into the board
Replace the component
Fill the hopper
Inspect and clear jam in the feed tube
Inspect the feed motor circuit (hopper lid must
be closed, vacuum switch must be closed (ie
exhaust blower on), and feed motor must be
plugged in.
Clean the fire pot
Check leads and if the igniter works.
Clean the end of the igniter chamber from
inside the firebox (removal of the fire pot
required for this step).
Review the feed motor and feed rates. Normal
feed motor operation is on between 1* and 4*
seconds out of every 7 seconds. (*depending
on model and burn rate setting)
If the feed motor does not turn off, replace the
control board.
Review the fuel being used.
Clean
Replace
Review the installation and move if necessary.