Please read this entire manual before installation and use of this pellet fuel-burning room heater, and save
for future reference. Failure to follow these instructions could result in property damage, bodily injury or even death. Contact
local building or fire officials about restrictions and installation inspection requirements in your area.
Note:
To obtain a French translation of this manual, please contact your dealer or visit www.pelprostoves.com. Pour obtenir
une traduction francaise de ce manuel, s'il vous plait contracter votre revendeur ou visitez
www.pelprostoves.com

Advertisement

Table of Contents
loading

Summary of Contents for Pelpro PPC90

  • Page 1 PelPro Cast Iron Pellet Stove . WARNING! Please read this entire manual before installation and use of this pellet fuel-burning room heater, and save for future reference. Failure to follow these instructions could result in property damage, bodily injury or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
  • Page 2: Table Of Contents

    Maintaining Your Stove ........18 Fire Risk Pelpro disclaims any responsibility, and the warranty and agency listing will be voided, by the below actions. •...
  • Page 3: Getting Started

    Getting Started Getting Started Getting Started Pallet Removal What You’ll Need There are bolts holding your PelPro Stove in place on the Pallet Removal pallet. To remove your Stove from the pallet: Visit pelprostoves.com Tools & Supplies or scan this code.
  • Page 4: Using Your Stove

    DO NOT INSTALL IN A SLEEPING ROOM. Consumes oxygen in the room. For Canada, the installation must conform to CAN/CSA-B365 PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 5: Vent Termination Clearances

    Side wall to Stove the vent vertically through the roof or above the roof Clearance to top of Stove Clearance to front of Stove 1219 PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 6: Venting Your Stove

    Length of Horizontal Sections (FT) Horizontal Run (FT) Horizontal Run, (ft) Length of Horizontal Sections (FT) covered breezeway, etc. • Excessive sooting PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 7: Using Your Stove

    Fuels with low mineral content • Most premium grade pellets Install outside air kit (included) For optimal performance, PelPro recommends the outside air kit for all installations. Outside air kit is required for all mobile/manu- factured home installations. Install through wall •...
  • Page 8: Starting Your Stove The First Time

    State of California to cause birth defects or other reproductive • Recommend the use of a surge protector harm. For more information go to: WWW.P65Warnings.ca.gov PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 9: Starting Your Stove From An Empty Hopper

    Smoke Hazard Thermostat Auger stops feeding pellets. Blowers continue to run until Your PelPro Stove comes with a built-in thermostat system that provides easy temperature after the exhaust temperature • Press power button on display to OFF, adjustments. An external thermostat is available as an option (sold separately). To use an has cooled.
  • Page 10: Maintaining Your Stove

    The gasket between the glass and firebox should be inspected periodically to make sure there is a good seal. Metal container Drop cloth Ash vacuum with lid PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 11 Your chimney should be inspected once every few months during the heating season to determine if a creosote or soot buildup has occurred. If creosote or soot has accumulated, it should be removed to reduce the risk of a chimney fire. PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com...
  • Page 12: Replacement Parts

    The left and right baffles have similar hooks Zone Zone and slots as the center baffle. Replacement kit: SRV7079-006 PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 13 6. Inspect the igniter from the front of the appliance by removing the firepot and looking into the end of the chamber (MAKE SURE The IGNITER IS CENTERED IN THE CHAMBER). Replacement kit: SRV7000-660 PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com...
  • Page 14: Troubleshooting

     Check passages to assure if not able, refer to page 10 for alternate installation options • If using a generator, Pelpro recommends a steady state they are clear of ash and generator for best Stove performance. obstructions. Poor airflow leads to poor performance •...
  • Page 15 Replace temperature. Installation Review the installation and move if necessary. Installation configuration is tight allowing for limited air circulation around the unit. PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 16: Warranty

    All replacement parts are covered for remainder of original warranty 90 Days period or 90 days, whichever is longer Additional terms and limitations apply. See page 30 for complete warranty information. PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 17: Listings And Certifications

    Listings and Certifications Glass Specifications This Stove is equipped with 5mm ceramic glass. Stove Certification Replace glass only with 5mm ceramic glass. Please contact PelPro for replacement glass. Electrical Rating (On High) Series PPC90/TSC90 Laboratory OMNI-Test Laboratories, Inc. PPC90/TSC90 Series: 115 VAC, 60 Hz, Start 2.6 Amps, Report No.
  • Page 18: Warranty

    Warranty Coverage: Subject to the table below, HHT warrants to the owner of the PelPro Stove that the Stove will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered components are found to be defective in materials or workmanship during the applicable warranty period, HHT will replace the covered components.
  • Page 19 SRV7093-184 18.2 Feed Shaft Bushing Pkg of 2 7000-600/2 Wire Harness Thermostat Block SRV7080-152 See Following page for additional servcie parts 1/21 PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...
  • Page 20: Maintenance Log

    Date Purchased / installed: ____________________________________________________ (Attach Proof of Purchase) Serial Number: ________________________ Location on Stove: _____________________ Store Purchased From: _______________________________________________________ Store Location: _____________________________________________________________ Maintenance Log: PelPro Cast Pellet Stove • 7093-600J • 04/21 pelprostoves.com pelprostoves.com PelPro Cast Pellet Stove • 7093-600J • 04/21...