Dometic TEC29 EV LPG Operating Manual page 20

Hide thumbs Also See for TEC29 EV LPG:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
Operating the generator
Display message
Description
OVER TEMPERATURE
Overheating
LOW POWER ENGINE
The inverter supply voltage has
dropped.
RESTART GEN?
Message appears after the gen-
erator has stopped due to over-
heating.
GEN CAL
Message appears when the gen-
erator is started up; it shows the
calibration phase which takes
place before each start-up. The
generator does not supply any
voltage.
GEN WAIT
Message appears while you are
waiting for the generator to start
again.
GEN ON
The generator is operating nor-
mally.
GEN OFF
AUTO?
Message appears when the
automatic mode is switched on.
AUTO
Automatic mode
20
Generator behaviour
The inverter switches off so no
voltage is supplied to cool the
generator, but the engine car-
ries on running.
The generator stops.
The generator is switched off.
The generator is running but
does not supply any voltage.
The generator is switched off.
Normal mode
The generator is in stand-by and
can be started.
Controls are waiting for user
input
The automatic mode is switched
on
TEC29 EV, TEC29 EV LPG
Measures
Leave the engine to cool down
for a few minutes then start the
generator again.
Reduce the connected load and
start the generator again.
Press the start button to restart
the generator.
Wait a moment.
Wait until the message has disap-
peared then attempt ignition
again.
Press the start button within
20 seconds and hold down for
3 seconds.
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tec29 evTec 29lpgTec 29

Table of Contents