Wiring Diagram: Outdoor Unit - Daikin RXYSQ6T7Y1B9 Installer's Manual

Vrv iv-s system air conditioner
Hide thumbs Also See for RXYSQ6T7Y1B9:
Table of Contents

Advertisement

13 Technical data
13.6

Wiring diagram: Outdoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.
L1 L2 L3 N
3N~ 50 Hz
Q1DI
380-415 V
X1M
L1 L2 L3 N
Z6C
N=1
Z8C N=3
L1A
L2A
L3A
NA
F1U
F2U
F5U
Z1F
Z2F
F3U
F4U
L11A
L21A
L31A
X8A
Z4C
N=1
L12A
L22A
L32A
X108A
K1M
V2R
C1
C2
R1
V1R
1 2
P1
P2
U
V
W
X32A
Z3C
Z8C
L1R
N=6
N=1
X1Y
1
2
3
MS
P>
M1C
3~
S1PH
Position in switchbox
A2P
A1P
A2P
X1M
X2M
Front side
Upper side
Notes for RXYSQ6_Y1:
1
Symbols (see below).
2
For X37A refer to the installation manual of the option.
3
Refer to the installation or service manual on how to use
BS1~BS4 push buttons, and DS1‑1 and DS1‑2 DIP switches.
4
Do not operate the unit by short-circuiting protection device
S1PH.
5
Refer to the installation manual for indoor-outdoor
transmission F1-F2 wiring.
6
When using the central control system, connect outdoor-
outdoor transmission F1-F2.
Symbols:
X1M
Main terminal
Earth wiring
15
Wire number 15
Field wire
Field cable
**
/12.2
Connection ** continues on page 12 column 2
1
Several wiring possibilities
Option
Not mounted in switch box
Wiring depending on model
Installer and user reference guide
44
-t°
Y1S
R1T
R2T
Z8C
N=1
Z2C
N=1
E
E1
X25A
X11A
1 2
1 2 3
K1R
1
3
1
3
X9A
X4A
X109A
X104A
1
3
1 3
V3R
K2R
PS
R3
R2
K1R
1 2
3
4
5
6 7
1 2
3
X107A
X106A
X2Y
X3Y
1
2 3 4 5
1
2 3 4 5
MS
MS
M1F
M2F
A1P
-t°
-t°
-t°
-t°
-t°
R3T
R4T
R5T
R6T
Z8C
N=1
X12A
X13A
1 2 3
4
5 6
7 8
1 2
H1P H2P H3P H4P H5P H6P H7P H8P
BS1 BS2 BS3
BS4 BS5
1 2 3 4 5
6
1 2 3 4 5 6
X21A
X22A
A2P
1 2 3
4
5
6
HAP
C3
F1U
M
Y1E
4
5
6 7
1 2
X111A
Z5C
-t°
R10T
N=1
PCB
Legend for wiring diagram RXYSQ6_Y1:
A1P
Printed circuit board (main)
A2P
Printed circuit board (inverter)
BS*
Push buttons (mode, set, return, test, reset) (A1P)
C*
Capacitor (A2P)
DS1
DIP switch (A1P)
F1U, F2U
Fuse (T 31.5 A / 500 V) (A1P)
F1U
Fuse (T 5.0 A / 250 V) (A2P)
F3U, F4U,
Fuse (T 6.3 A / 250 V) (A1P)
F5U
H*P
LED (service monitor orange) (A1P)
HAP
Running LED (service monitor green) (A*P)
K1M
Magnetic contactor (A2P)
K*R
Magnetic relay (A*P)
L1R
Reactor
M1C
Motor (compressor)
M1F
Motor (upper fan)
M2F
Motor (lower fan)
PS
Switching power supply (A2P)
Q1DI
Earth leakage circuit breaker (field supply)
R*
Resistor (A2P)
R1T
Thermistor (air)
-t°
S1NPL
S1NPH
R7T
X5Y
X4Y
X17A
X18A
3 4 5 6
1 2 3 4
1 2 3 4
HAP
ON
DS1
OFF
1 2
1 2 3 4 5 6
1 2
3
1 2 3 4
X50A
cool/heat
selector
cable option.
X2M A B C
F1 F2 F1 F2
M
Y3E
A
COOL
HEAT
S2S
B
FAN
AIR
CONTROL
S1S
C
Cool / heat selector option.
4D094014-1C
RXYSQ6T7Y1B9
VRV IV-S system air conditioner
4P404677-1A – 2016.03
Z8C
N=1
A1P
X37A
1
note 2
2
5 6
X81A
Z7C
N=1
Switch box
note 6