For The User; 14 About The System; System Layout; User Interface - Daikin RXYSQ6T7Y1B9 Installer's Manual

Vrv iv-s system air conditioner
Hide thumbs Also See for RXYSQ6T7Y1B9:
Table of Contents

Advertisement

For the user

14
About the system
The indoor unit part of VRV IV-S heat pump system can be used for
heating/cooling applications. The type of indoor unit which can be
used depends on the outdoor units series.
NOTICE
Do not use the air conditioner for other purposes. In order
to avoid any quality deterioration, do not use the unit for
cooling precision instruments, food, plants, animals or
works of art.
NOTICE
For future modifications or expansions of your system:
A full overview of allowable combinations (for future
system extensions) is available in technical engineering
data and should be consulted. Contact your installer to
receive more information and professional advice.
In general following type of indoor units can be connected to a VRV
IV-S heat pump system (not exhaustive list, depending on outdoor
unit model and indoor unit model combinations):
▪ VRV direct expansion indoor units (air to air applications).
For more specifications, see technical engineering data.
14.1

System layout

a
b
c
c
d
d
a
VRV IV-S Heat pump outdoor unit
b
Refrigerant piping
c
VRV direct expansion (DX) indoor unit
d
User interface (dedicated depending on indoor unit type)
15

User interface

CAUTION
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch and appliance problems may happen.
For checking and adjusting the internal parts, contact your
dealer.
This operation manual will give a non-exhaustive overview of the
main functions of the system.
Detailed information on required actions to achieve certain functions
can be found in the dedicated installation and operation manual of
the indoor unit.
Refer to the operation manual of the installed user interface.
RXYSQ6T7Y1B9
VRV IV-S system air conditioner
4P404677-1A – 2016.03
16

Before operation

WARNING
This unit contains electrical and hot parts.
WARNING
Before operating the unit, be sure the installation has been
carried out correctly by an installer.
CAUTION
It is not good for your health to expose your body to the air
flow for a long time.
CAUTION
To avoid oxygen deficiency, ventilate the room sufficiently
if equipment with burner is used together with the air
conditioner.
CAUTION
Do not operate the air conditioner when using a room
fumigation-type
insecticide.
chemicals to become deposited in the unit, which could
endanger the health of those who are hypersensitive to
chemicals.
This operation manual is for the following systems with standard
control. Before initiating operation, contact your dealer for the
operation that corresponds to your system type and mark. If your
installation has a customised control system, ask your dealer for the
operation that corresponds to your system.
Operation modes (depending on indoor unit type):
▪ Heating and cooling (air to air).
▪ Fan only operation (air to air).
Dedicated functions exist depending on the type of indoor unit, refer
to dedicated installation/operation manual for more information.
17

Operation

17.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
Cooling
Outdoor
–5~46°C DB
temperature
Indoor
21~32°C DB
temperature
14~25°C WB
Indoor humidity
(a)
To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.
Above operation range is only valid in case direct expansion indoor
units are connected to the VRV IV-S system.

14 About the system

This
could
cause
the
Heating
–20~21°C DB
–20~15.5°C WB
15~27°C DB
(a)
≤80%
Installer and user reference guide
49

Advertisement

Table of Contents
loading

Table of Contents