ALARM IN connections
Connect external sensors to the 8-pin haness connec-
tor. Each alarm sensor should be connected with G
(GND). Input specifications are low-active, non-volt-
age contact (ON when active) or open collector (Low
when active).
Cautions
•
Alarm input connection must be connected to only
one port of two communication ports.
•
Do not connect one alarm sensor to the several
camera's alarm input connector.
Data Port A Adapter
Data Port B
16
Alarm
sensors (1-4)
Adapter
Alarm
sensors (5-8)
Connection of the data port and adapter
for alarm input
•
Data Port A
No
Description
1
ALARM IN 1
2
ALARM IN 2
3
GND
4
TRX D -
5
TRX D +
6
GND
7
ALARM IN 3
8
ALARM IN 4
No
Description
1
ALARM IN 1
2
ALARM IN 2
3
GND
4
TRX D -
5
TRX D +
6
GND
7
ALARM IN 3
8
ALARM IN 4
Alarm sensor 4
Alarm sensor 3
Alarm sensor 2
Alarm sensor 1
Color
Black
Brown
Red
Orange
Yellow
Green
Blue
White
Color
Brown
Blue
Yellow
Green
Red
Black
Orange
White