Connection

Precautions

The connections should be made by qualified ser-
vice personnel or system installers in accordance
with all local codes.
AC 24V can be used.
Note:
When powered up, the unit performs a self-check
(including one panning, tilting, zooming and focus-
ing operation).

Connection preview

AC 24V
Video output
data port A
data port B
data port C Ethernet cable

RS-485 connection

Use the cable that is described below for RS-485 site
communication.
Shielded, twisted pair cable
Low impedance
Wire gauge size is thicker than AWG #22 (0.33 mm

Connecting monitor

The video signal connection between the camera and
the monitor.
AC 24V cable for
Camera
BNC plug
Ethernet cable
Ethernet cable

Connecting power source

Connect a AC 24 V power source to the power input
terminal.