Alarm Output Connections - LG LW9228 Series Owner's Manual

Network dome camera
Hide thumbs Also See for LW9228 Series:
Table of Contents

Advertisement

14
Installation
PORT A of the LW9228I/9226I series
Description
RS-485 +
RS-485 -
NC
ALARM IN COM
ALARM IN 1
ALARM IN 2
ALARM IN 3
3
ALARM IN 4
PORT A of the LW9228/9226 series
Description
RS-485 +
RS-485 -
NC
ALARM IN COM
ALARM IN 1
ALARM IN 2
ALARM IN 3
ALARM IN 4
NOTE
RS-485 data communication is not available.
Color
Red/White
Black/White
Red
White
Light Green
Yellow
Pink
Color
Green
Blue
Yellow
Pink
Gray
White
Violet

ALARM output connections

Connect the alarm device to the alarm output data port.
Alarm signal output at an event occurrence. You can set the
Alarm Output to the normal open or normal close mode.
1. Connect the RJ-45 Adapter cable to the PORT B (RJ-45)
cable of the camera.
2. Connect the alarm device to the RJ-45 Adapter cable.
When connecting lines, check and connect the color
lines of the each device correctly. Refer to the below
tables for color line information.
Alarm Out connection
A
B
C
D
E
F
G
H
RJ-45 Adapter cable
RJ-45 Adapter cable
RJ-45 Adapter cable
No
Description
A
ALARM OUT [NO1]
ALARM OUT [COM1]
B
C
ALARM OUT [NC1]
NC
D
ALARM OUT [NO2]
E
ALARM OUT [COM2]
F
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Alarm device
Port B
PORT B
Color
White
Orange
Black
Red
Green
Yellow