- Valid range
Bit
Terminal
0
1
2
3
4
5
6-15
If multiple digital output control signals are used at the same time, the output value is the OR of all digital
output controls.

6.5.7. nviAnalogOut1,2 (Control of Analog output)

Input network variable (Reserved)
SNVT type: SNVT_lev_percent (81)
They enable the analog output control.
- Valid range: 0.000 to 100.000%
- Unit: 0.005% (The resolution depends on the inverter specification)
When the variables will be used, the inverter parameters must be assigned.
Name
nviAnalogOut1
nviAnalogOut2

6.5.8. nviEmergOverride (Emergency stop)

Input network variable
SNVT type: SNVT_have_emerg (103)
It provides an emergency stop of the motor. Emergency stop can be configured by Emergency stop
selection (f603) to coast stop, slow down stop or emergency DC braking (refer to the inverter
instruction manual for details).
- Valid range
Value
0
1
2
3
4
5
6 to 255
N.B.: "Remove emergency" command clears a fault and resets the inverter.
LIU007Z
Parameter
---
---
---
---
---
---
---
---
---
---
---
---
---
---
(Output value is not adjusted by the inverter parameter "fm", "am")
LIU007Z
Terminal
---
---
Command
Remove emergency EMERG_NORMAL (No Emergency mode)
EMERG_PRESSURIZE (Emergency pressurize mode)
EMERG_DEPRESSURIZE (Emergency depressurize mode)
EMERG_PURGE (Emergency purge mode)
Emergency stop
EMERG_SHUTDOWN (Emergency shutdown mode)
EMERG_FIRE (Emergency fire mode)
---
LIU006Z
Terminal
Under Development
Parameter
Terminal
---
Under Development
---
- 25 -
Parameter
LIU006Z
Parameter
Description
E6581373