Command & Setpoint Selection (Local/Remote) - Toshiba TOSVERT VF-FS1 Series Function Manual

Lonworks option unit - communication function manual
Hide thumbs Also See for TOSVERT VF-FS1 Series:
Table of Contents

Advertisement

3.6. Command & Setpoint selection (Local/Remote)
Indication to display Local/Remote mode is on the inverter unit (Refer to the inverter instruction manual
for details). L
ON
option unit propagates the Local / Remote status to the network as the "Command from the network
(bit5)" and "Setpoint from the network (bit6)" in "nvoStatusWord" network variable. Inverters have some
switches to select the command and setpoint location. Following figure shows the diagram. Refer to the
inverter instruction manual for the parameter in detail.
*1: Be careful that cmod command and fmod setpoint are activated for a short time just after the
inverter power turned on. Set cmod and fmod to "Serial communication"
problem.
LIU007Z
Control Terminal
Operation Panel
Serial Comm.(L
Operation Panel
Serial Comm. (L
W
option command and setpoint are activated on Remote mode
ORKS
cmod
0
1
2
W
)
ON
ORKS
fmod
VIA
1
VIB
2
3
W
)
4
ON
ORKS
UP/DOWN
5
Logic input = 48 (SC/LC)
Network cancel switch
1
Serial Comm.
0
(L
W
)
ON
ORKS
1
Serial Comm.
0
(L
W
)
ON
ORKS
- 10 -
E6581373
*1
. L
ON
to prevent this
Local/Remote key
Rem
Loc
Operation
Panel
Rem
Loc
Operation
Panel
W
ORKS
Command
Setpoint