In a value setting window, turn the dial clockwise or counterclockwise to increment or
decrement the value displayed, and press the dial to confirm the value specified.
Turn the dial clockwise (+) to increment the value.
Turn the dial counterclockwise (-) to decrement the value.
Turning the dial clockwise or counterclockwise to increment or decrement the value
displayed and pressing the dial to confirm the value specified are referred to as
"specify/confirm a value."
*1: When the control dial is pressed, it performs the same function as the [ENT] key
on the inverter's main operation panel.
*2: Some settings are executed only by tuning the control dial.
LCD panel
This section explains the features of windows available, using the top window of
Status Monitor Mode as an example.
(1) Displays the mode currently selected.
(2) Displays the operating status of the inverter in a graphical symbol.
(rotating)
EOFF (blinking)
(3) Displays the title or status of the window.
(4) Displays settings both in a menu form and numerically, or a list of various kinds of
information.
(5) Displays the function assigned to each function key in an abbreviation or graphical
symbol.
The abbreviations and graphical symbols in the window correspond to the [F1] to
[F4] keys, respectively starting from the left.
Top : In this example, pressing the [F1] key displays the Top View Mode window.
: In this example, pressing the [F2] key displays the previous window.
: In this example, pressing the [F3] key displays the next window.
Prm : In this example, pressing the [F4] key displays the Parameter Setting Mode
window.
⇒ Refer to "8. List of function key functions"
(6) Graphical symbols displayed vary depending on whether there are windows that
precede or follow the current window.
: There are windows that precede and/or follow the current window.
: There is no window that precedes or follows the current window.
(1)
Status Monitor Mode
Real-time information
Rotative direction
Frequency reference
Output current
Input voltage
Output voltage
Top
: In operation
: Operation impossible (While the frequency is set at 0Hz, the
[RUN] key is pressed.)
: Waiting for emergency stop operation
1-2
1. Names and functions
(2)
(3)
FWD
60.0Hz
(4)
90%
99%
99%
(5)
Prm
(6)
*2