5. Operation in Top View Mode
(1) Function of switching between Quick mode and Standard Setting mode
<Standard Setting mode selected when power is turned on (parameter PSEL=0)>
• When power is turned on, "Quick" is displayed. (If the [F1] key is not pressed.)
When the unit enters Parameter Setup Mode in this situation, the ordinary top
window of Parameter Setup Mode appears.
• If the [F1] key is pressed while "Quick" is displayed, "Quick" is switched from
normal to reverse video "
When the unit enters Parameter Setup Mode in this situation, the Quick mode
window appears instead of the top window of Parameter Setup Mode.
<Quick mode selected when power is turned on (parameter PSEL=1)>
• When power is turned on, "
is not pressed.)
When the unit enters Parameter Setup Mode in this situation, the Quick mode
window appears instead of the top window of Parameter Setup Mode.
• If the [F1] key is pressed when "
switched from reverse to normal video. (If the [F1] key is pressed.)
When the unit enters Parameter Setup Mode in this situation, the ordinary top
window of Parameter Setup Mode appears.
<Always Quick mode (parameter PSEL=2)>
• "
Quick
When the unit enters Parameter Setup Mode in this situation, the Quick mode
window appears instead of the top window of Parameter Setup Mode.
* In this situation, the [F1] key is inoperative.
(2) Operation Panel and Remote (When used with a VF-AS1 inverter)
• "Panel" is displayed. (If the [F1] key is not pressed.)
In this situation, operation can be performed by remote control by means of the
terminal board.
• If the [F1] key is pressed while "Panel" is displayed, "Panel" is switched from
normal to reverse video "
In this situation, operation can be performed using keys on the remote keypad.
There is no need to switch to Panel Operation mode by changing parameter
settings.
* The switching between operation modes cannot be done during operation.
(3) Operation Panel and Remote (When used with a VF-PS1 inverter)
• "Loc/
Rem
In this situation, operation can be performed by remote control by means of the
terminal board.
• If the [F1] key is pressed while "Panel" is displayed, "Loc/
normal to reverse video "
In this situation, operation can be performed using keys on the remote keypad.
There is no need to switch to Local Operation mode by changing parameter
settings.
* The switching between operation modes cannot be done during operation.
Quick
Quick
" is displayed in reverse video.
Panel
" is displayed. (If the [F1] key is not pressed.)
Loc
/Rem". (If the [F1] key is pressed.)
". (If the [F1] key is pressed.)
" is displayed in reverse video. (If the [F1] key
" is displayed in reverse video, "Quick" is
Quick
". (If the [F1] key is pressed.)
5-3
Rem
" is switched from