Download Print this page

Sharp AR-M155X Service Manual page 79

Digital multifunctional system

Advertisement

Main
Sub
Contents
code
code
26
02
(R)SPF setting (SPF/RSPF)
(Executable only when the
SPF/RSPF is installed.)
03
Second cassette setting
(2ND TRAY)
04
Main unit duplex setting
(DPLX) (Executable only
when the RSPF is installed.)
06
Destination setting
(DESTINATION)
07
Machine conditions check
(CPM)
20
Rear edge void setting (END
EDGE)
[Function]
When this test command is executed, the current set SPF is displayed. Enter the code number corre-
sponding to the desired SPF and press [OK (ENTER)/START] key to save the setting.
Code number
0
SPF NO
1
SPF YES
2
RSPF YES
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set second cassette is displayed. Enter the code
number corresponding to the desired second cassette and press [OK (ENTER)/START] key to save
the setting.
Code number
Second cassette
0
Second cassette NO
1
Second cassette YES
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set duplex is displayed. Enter the code number cor-
responding to the desired duplex and press [OK (ENTER)/START] key to save the setting.
Code number
0
Duplex NO
1
Duplex YES
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current set destination is displayed. Enter the code number
corresponding to the desired destination and press [OK (ENTER)/START] key to save the setting.
Code number
0
Inch series
1
EX Japan AB series
2
Japan AB series
3
China (EX Japan AB series + China paper support)
For Japan AB series, there is no schedule for production.
[Operation]
The operation is similar to test command 21-01.
[Function]
When this test command is executed, the current machine setting is displayed.
CPM
10 CPM
12 CPM
13 CPM
14 CPM
15 CPM
16 CPM
[Operation]
1) The machine setting is displayed.
26-07 CPM
10 CPM
[Function]
When this test command is executed, the current set rear edge void is displayed. Enter the code num-
ber corresponding to the desired rear edge void and press [OK (ENTER)/START] key to save the set-
ting.
Code number
0
Rear edge void NO
1
Rear edge void YES
[Operation]
The operation is similar to test command 21-01.
AR-M150/M155/M155X TEST COMMAND, TROUBLE CODES 10 - 13
Details of function/operation
SPF
Display item
SPF OFF
SPF ON
RSPF ON
Display item
OFF
ON
Duplex
Display item
OFF
ON
Destination
Coy quantity
Remark
10
12
13
14
15
16
Setting
Display item
OFF
ON
Display item
INCH
AB
CHINA
Remark
Default