5) Remove three E-rings and remove the manual paper feed roller
B9.
1)
1)
1)
3)
O
6) Remove the pick-up roller.
2)
1)
2)
AR-M150/M155/M155X DISASSEMBLY AND ASSEMBLY 8 - 16
7) Cut the binding band and remove the multi paper feed solenoid.
Multi paper feed
solenoid
C. Assembly procedure
For assembly, reverse the disassembly procedure.
D. Pressure plate holder attachment
1) Attach the pressure plate holder so that the resin section is not
covered with the seal M1-N.
Seal M1-N
Attachment
reference
Attachment
reference
1)
3)
2)
Pressure plate
holder