6 PARAMETER LIST

For simple variable-speed operation of the inverter, the initial setting of the parameters may be used as they are. Set the
necessary parameters to meet the load and operational specifications. Parameter setting, change and check can be made
from the operation panel. For details of parameters, refer to the instruction manual.
In the initial setting, only the simple mode parameters are displayed.
Set Pr. 160 Extended function display selection as required.
Parameter
Name
Extended function
160
display selection
REMARKS
indicates simple mode parameters.
The parameters surrounded by a black border in the table allow its setting to be changed during operation even if "0" (initial
value) is set in Pr. 77 Parameter write selection.
Name
Parameter
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
Multi-speed setting (high
4
speed)
Multi-speed setting (middle
5
speed)
Multi-speed setting (low
6
speed)
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
DC injection brake operation
10
frequency
DC injection brake operation
11
time
DC injection brake operation
12
voltage
13
Starting frequency
14
Load pattern selection
15
Jog frequency
Jog acceleration/deceleration
16
time
17
MRS input selection
High speed maximum
18
frequency
19
Base frequency voltage
Acceleration/deceleration
20
reference frequency
22
Stall prevention operation level 0 to 200%
Initial
Setting
Value
Range
9999
9999
0
Setting
Initial
Range
Value
0 to 30%
6/4/3%
∗1
0 to 120Hz
120Hz
0 to 120Hz
0Hz
0 to 400Hz
50Hz
0 to 400Hz
50Hz
0 to 400Hz
30Hz
0 to 400Hz
10Hz
0 to 3600s
5/10s
∗2
0 to 3600s
5/10s
∗2
Rated
0 to 500A
inverter
current
0 to 120Hz
3Hz
0 to 10s
0.5s
0 to 30%
6/4%
∗3
0 to 60Hz
0.5Hz
0 to 3
0
0 to 400Hz
5Hz
0 to 3600s
0.5s
0, 2, 4
0
120 to 400Hz
120Hz
0 to 1000V,
8888
8888, 9999
1 to 400Hz
50Hz
150%
Remarks
Only the simple mode parameters can be displayed.
Simple mode and extended mode parameters can be
displayed.
Name
Parameter
Stall prevention operation level
23
compensation factor at double
speed
24
Multi-speed setting (speed 4)
25
Multi-speed setting (speed 5)
26
Multi-speed setting (speed 6)
27
Multi-speed setting (speed 7)
Acceleration/deceleration
29
pattern selection
Regenerative function
30
selection
31
Frequency jump 1A
32
Frequency jump 1B
33
Frequency jump 2A
34
Frequency jump 2B
35
Frequency jump 3A
36
Frequency jump 3B
37
Speed display
RUN key rotation direction
40
selection
41
Up-to-frequency sensitivity
42
Output frequency detection
Output frequency detection for
43
reverse rotation
Second acceleration/
44
deceleration time
PARAMETER LIST
Setting
Initial
Range
Value
0 to 200%,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0, 1, 2
0, 1, 2
0 to 400Hz,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0 to 400Hz,
9999
0, 0.01 to
9998
0, 1
0 to 100%
0 to 400Hz
0 to 400Hz,
9999
0 to 3600s
5/10s
9999
9999
9999
9999
9999
0
0
9999
9999
9999
9999
9999
9999
0
0
10%
6Hz
9999
∗2
13

Hide quick links:

Advertisement