Samsung NX58R4311SS Service Manual page 52

Freestanding gas ranges
Table of Contents

Advertisement

4. Troubleshooting
4-2 Cooktop Malfunction
The flame looks abnormal (Gas)
Yellow tip / Lift flame
BURNER ORIFICE SIZES AND OUTPUT RATINGS
Burner location
1. MODEL NX58F5500SS / NX58F5500SB / NX58F5300SS / NX58R4311SS / NX58R4311SG
2. MODEL NX58F5300SS
*Check whether the burner heads
and caps are properly assembled.
Ok
*Check the orifice nozzle diameter.
[NG / LP]
Ok
*Check the direction of the
orifice at the GPR.
Ok
*Check the air shutter opening
[Broil / Bake burner]
Ok
END
This document can not be used without Samsung's authorization.
(Natural Gas 5 in WCP)
BTU Rate
Orifice Size [mm]
1
RF
17,000
2
RF
16,000
LF
12,000
RR
5,000
LR
9,500
1
CTR
9,500
CTR
2
9,500
BAKE
18,000
BROIL
13,500
No
No
No
No
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner location
1.92
RF
1.92
LF
1.60
RR
1.01
LR
1.40
1
CTR
1.38
2
CTR
1.40
BAKE
1.90
BROIL
1.64
*Place the burner heads and caps
properly.
*Replace the orifice nozzle.
*Apply the right direction of the orifice.
*Adjust the air shutter opening.
52
BTU Rate
Orifice Size [mm]
12,500
1.06
10,000
0.98
4,000
0.62
7,500
0.83
7,500
0.83
7,500
0.83
15,000
1.15
11,500
1.02
END
END
END
END