3. Disassembly and Reassembly
3-20 Replacing the Assy Valve Safety
Parts
Assy Valve
Safety
This document can not be used without Samsung's authorization.
Explanation Photo
WIRES
33
Explanation
8. Install the new ASSY VALVE
SAFETY from the back wall of the
warming drawer with 4 screws.
9. Reconnect gas lines to the ASSY
VALVE SAFETY .
NOTE: Check all gas lines and fittings
for leaks before operation.
WARNING
Cross-wiring the wires to the gas
control valve creates an explosion
hazard that can result in death,
personal injury, and/or property
and product damage.
10. Reconnect wire connectors in their
original positions.